Engineering Department, Tokyo Metropolitan Sewerage Service Co., Ltd., 2-6-2 Ootemati, Chiyoda-ku Tokyo, 100-8699, Japan.
Water Sci Technol. 2009;60(9):2291-9. doi: 10.2166/wst.2009.654.
A new optical fiber flow velocity sensor was developed by using an optical fiber information network system in sewer drainage pipes. The optical fiber flow velocity sensor operates without electric power, and the signals from the sensor can be transmitted over a long distance through the telecommunication system in the optical fiber network. Field tests were conducted to check the performance of the sensor in conduits in the pumping station and sewage pond managed by the Tokyo Metropolitan Government. Test results confirmed that the velocity sensor can be used for more than six months without any trouble even in sewer drainage pipes.
一种新型的光纤流速传感器,通过利用光纤信息网络系统,在排水管道中得以开发。该光纤流速传感器无需电力运行,其传感器信号可以通过光纤网络中的通信系统远距离传输。在东京都政府管理的泵站和污水池的管道中进行了现场测试,以检查传感器的性能。测试结果证实,即使在排水管道中,该流速传感器也可以无故障使用超过六个月。