Suppr超能文献

人体对 1800 微特斯拉、60 赫兹磁场的急性暴露的心血管反应。

The cardiovascular response to an acute 1800-microT, 60-Hz magnetic field exposure in humans.

机构信息

Bioelectromagnetics, Imaging Program, Lawson Health Research Institute, 268 Grosvenor Street, N6A 4V2, London, ON, Canada.

出版信息

Int Arch Occup Environ Health. 2010 Apr;83(4):441-54. doi: 10.1007/s00420-009-0484-8. Epub 2009 Nov 10.

Abstract

PURPOSE

Previously published literature has suggested an effect of extremely low-frequency (ELF) magnetic fields (MF) on human heart rate (HR) and heart rate variability (HRV). The combined response of the microcirculation and macrocirculation to ELF MF exposure has not previously been studied in humans. This study investigated the effects of 1-h exposure to an 1800-muT, 60-Hz MF on human microcirculation (represented in this study as skin blood perfusion), HR, low-frequency HRV, and high-frequency HRV.

METHODS

Fifty-eight volunteers were recruited to partake in a double-blinded, counterbalanced study consisting of two testing sessions (real and sham) administered on separate days. Each session included four consecutive blocks of measurements, separated by 15-min rest periods, allowing measurement of cumulative and residual MF effects. Within subjects, ANOVA were conducted on each of the measured parameters.

RESULTS

A decrease of skin blood perfusion and HR, and an increase of HRV were observed over blocks (p < 0.05). No session by block interactions were found for any of the cardiovascular parameters which would have suggested a MF effect (p > 0.05). A session by block interaction (p < 0.001) and a MF order effect (sham or real exposure first, p < 0.05) were observed for skin surface temperature.

CONCLUSIONS

The MF used in this experiment did not affect cardiovascular parameters. Although an alternative explanation for why skin surface temperatures decreased in the sham and not in the real exposure condition is presented, the possibility of a MF effect cannot be excluded.

摘要

目的

先前的文献表明,极低频(ELF)磁场(MF)对人体心率(HR)和心率变异性(HRV)有影响。ELF MF 暴露对微循环和大循环的综合反应以前尚未在人体中研究过。本研究调查了 1 小时暴露于 1800μT、60Hz MF 对人体微循环(在本研究中表示为皮肤血液灌注)、HR、低频 HRV 和高频 HRV 的影响。

方法

招募了 58 名志愿者参加一项双盲、对照研究,该研究由两个测试阶段(真实和假)组成,分别在不同的日子进行。每个阶段包括四个连续的测量块,每个块之间间隔 15 分钟的休息时间,允许测量累积和剩余 MF 效应。对每个测量参数进行了每个受试者的方差分析。

结果

在块之间观察到皮肤血液灌注和 HR 减少,HRV 增加(p < 0.05)。对于任何心血管参数,都没有发现测试阶段与块之间的相互作用,这表明没有 MF 效应(p > 0.05)。皮肤表面温度出现了测试阶段与块之间的相互作用(p < 0.001)和 MF 顺序效应(先进行假暴露或真实暴露,p < 0.05)。

结论

本实验中使用的 MF 未影响心血管参数。尽管提出了为什么皮肤表面温度在假暴露而不是真实暴露条件下降低的替代解释,但不能排除 MF 效应的可能性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验