Carr Brian J, Ochoa Leah, Rankin David, Owens Brett D
William Beaumont Army Medical Center, El Paso, Texas, USA.
Orthopedics. 2009 Nov;32(11):828. doi: 10.3928/01477447-20090922-11.
Biologic reactivity to suture materials can have an effect on patient outcomes. The goal of this study was to determine the histologic response to 8 commonly used orthopedic sutures--Ethibond (Ethicon, Somerville, New Jersey), Ticron (Tyco, Waltham, Massachusetts), HiFi (Linvatec, Largo, Florida), Ultrabraid (Smith & Nephew, Memphis, Tennessee), MaxBraid (Biomet, Warsaw, Indiana), Orthocord (Mitek, Raynham, Massachusetts), MagnumWire (Opus Medical, San Juan Capistrano, California), and FiberWire (Arthrex, Naples, Florida)--using a rabbit model. The suture granuloms were evaluated at 30, 60, and 120 days with measurement of the fibrous capsule, the number of giant cells in and near the capsule, and the overall inflammatory grade: 1 (mild), 2 (moderate), and 3 (severe). MagnumWire and Ticron sutures initiated a more intense inflammatory reaction when compared to the other sutures. By 120 days, MagnumWire (P=.0297) and Ticron (P=.1855) had fewer giant cells at the soft tissue-suture interface, fewer giant cells within the capsule (P=.0074 and P=.0377, respectively), and the greatest capsular thickness of all suture types (P<.0001 and P=.1378, respectively). Differences exist between the biologic reactivity of commonly used orthopedic sutures that may be attributable to their material composition and/or braid characteristics. In comparison to other high-strength sutures, MagnumWire and Ticron stimulated a more intense foreign body inflammatory response.
对缝合材料的生物反应性可能会影响患者的治疗结果。本研究的目的是使用兔模型确定8种常用骨科缝线(Ethibond(Ethicon公司,新泽西州萨默维尔)、Ticron(泰科公司,马萨诸塞州沃尔瑟姆)、HiFi(Linvatec公司,佛罗里达州拉戈)、Ultrabraid(施乐辉公司,田纳西州孟菲斯)、MaxBraid(Biomet公司,印第安纳州华沙)、Orthocord(Mitek公司,马萨诸塞州雷纳姆)、MagnumWire(Opus Medical公司,加利福尼亚州圣胡安卡皮斯特拉诺)和FiberWire(Arthrex公司,佛罗里达州那不勒斯))的组织学反应。在第30、60和120天对缝线肉芽肿进行评估,测量纤维囊、囊内和囊附近的巨细胞数量以及总体炎症分级:1级(轻度)、2级(中度)和3级(重度)。与其他缝线相比,MagnumWire和Ticron缝线引发的炎症反应更强烈。到120天时,MagnumWire(P = 0.0297)和Ticron(P = 0.1855)在软组织-缝线界面处的巨细胞较少,囊内的巨细胞也较少(分别为P = 0.0074和P = 0.0377),并且在所有缝线类型中囊的厚度最大(分别为P < 0.0001和P = 0.1378)。常用骨科缝线的生物反应性之间存在差异,这可能归因于它们的材料成分和/或编织特性。与其他高强度缝线相比,MagnumWire和Ticron刺激了更强烈的异物炎症反应。