Suppr超能文献

咬合记录材料的垂直尺寸稳定性和刚性。

Vertical dimensional stability and rigidity of occlusal registration materials.

作者信息

Walker Mary P, Wu Edis, Heckman M Elizabeth, Alderman Nicholas

机构信息

University of Missouri, Kansas City School of Dentistry, MO, USA.

出版信息

Gen Dent. 2009 Sep-Oct;57(5):514-8.

Abstract

Dimensionally accurate occlusal registration records are essential for restorative dentistry; moreover, since records are not used immediately or may be used more than once, the registration material should exhibit accuracy over time (a concept known as dimensional stability). It has been speculated that materials with increased hardness or rigidity should produce more accurate registration records due to an increased resistance to distortion. This study compared the rigidity and associated dimensional accuracy of a recently marketed bisacrylic occlusal registration material and a vinyl polysiloxane (VPS). Maxillary and mandibular typodont arches were mounted on a plasterless articulator from which teeth No. 3, 13, and 15 had been removed to simulate edentulous spaces. After preparing teeth No. 2, 4, 12, and 14 as bridge abutments, the remaining teeth were equilibrated selectively to produce even anterior contact. Four digital photographs were taken to make vertical interarch measurements at four locations (teeth No. 3, 7, 10, and 14). Following initial photos (controls), 10 interocclusal records were made using each registration material, with material placed only in the segments in which teeth were prepared. The records were used for mounting the maxillary arch against the mandibular arch after 48, 72, and 120 hours. There were significant effects on vertical dimensional change related to arch location, material, and mounting time. Both materials demonstrated significantly larger posterior vertical openings than anterior vertical openings, while the bisacrylate produced a larger posterior opening than VPS at 48 and 72 hours and a larger anterior opening at all mounting times. There also was a significant difference in hardness/rigidity due to material and measurement time; at all measurement times, bisacrylate exhibited a significantly higher hardness number.

摘要

尺寸精确的咬合记录对修复牙科至关重要;此外,由于记录并非立即使用或可能会被多次使用,记录材料应随时间推移保持准确性(这一概念称为尺寸稳定性)。据推测,硬度或刚性增加的材料由于抗变形能力增强,应能产生更精确的记录。本研究比较了一种最近上市的双丙烯酸酯类咬合记录材料和一种乙烯基聚硅氧烷(VPS)的刚性及相关尺寸精度。将上颌和下颌典型牙弓安装在无石膏的牙合架上,移除3号、13号和15号牙以模拟无牙间隙。将2号、4号、12号和14号牙制备为桥基牙后,对其余牙齿进行选择性调牙合以实现均匀的前牙接触。拍摄四张数码照片,在四个位置(3号、7号、10号和14号牙)进行垂直牙弓间测量。在拍摄初始照片(对照)后,使用每种记录材料制作10份牙合间记录,材料仅放置在制备了牙齿的节段中。记录分别在48小时、72小时和120小时后用于将上颌牙弓与下颌牙弓进行上架。牙弓位置、材料和上架时间对垂直尺寸变化有显著影响。两种材料的后部垂直开口均明显大于前部垂直开口,而双丙烯酸酯类材料在48小时和72小时时的后部开口比VPS大,在所有上架时间的前部开口均更大。材料和测量时间对硬度/刚性也有显著差异;在所有测量时间,双丙烯酸酯类材料的硬度值均显著更高。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验