The comparison of two classifications for trochanteric femur fractures: the AO/ASIF classification and the Jensen classification.

机构信息

Department of Surgery, Medisch Centrum Haaglanden, The Hague, The Netherlands.

出版信息

Injury. 2010 Apr;41(4):377-81. doi: 10.1016/j.injury.2009.10.007. Epub 2009 Nov 10.

Abstract

This study compares the reproducibility of two classifications for trochanteric femur fractures: the Jensen classification and the AO/ASIF classification. Furthermore we evaluated the agreement on fracture stability, choice of osteosynthesis, fracture reduction and the accuracy of implant positioning. In order to calculate the inter-, and intra-observer variability 10 observers classified 50 trochanteric fractures. The inter-observer agreement of the AO/ASIF classification and the Jensen classification was kappa0.40 and kappa0.48. The kappa coefficient of the intra-observer reliability of the AO/ASIF classification was kappa0.43 and kappa0.56 for the Jensen classification. Preoperative agreement on fracture stability and type of implant showed kappa values of kappa0.39 and kappa0.65. The postoperative agreement on choice of implant, fracture reduction and position of the implant was kappa0.17, kappa0.29 and kappa0.22, respectively. Both classifications showed poor reproducibility. This study suggests that the definition of stability of trochanteric fractures remains controversial, which possibly complicates the choice of osteosynthesis.

摘要

本研究比较了两种用于转子间股骨骨折的分类法(Jensen 分类和 AO/ASIF 分类)的可重复性。此外,我们还评估了骨折稳定性、内固定选择、骨折复位和植入物定位准确性的一致性。为了计算观察者间和观察者内的变异性,10 名观察者对 50 例转子间骨折进行了分类。AO/ASIF 分类和 Jensen 分类的观察者间一致性的kappa 值分别为 0.40 和 0.48。AO/ASIF 分类的观察者内可靠性的kappa 值为 0.43,而 Jensen 分类的 kappa 值为 0.56。骨折稳定性和植入物类型的术前一致性的 kappa 值分别为 0.39 和 0.65。术后植入物选择、骨折复位和植入物位置的一致性的 kappa 值分别为 0.17、0.29 和 0.22。两种分类法的可重复性均较差。本研究表明,转子间骨折稳定性的定义仍存在争议,这可能使内固定物的选择复杂化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验