Department of Orthopaedic surgery, Omigawa general hospital, Chiba, Japan.
Spine (Phila Pa 1976). 2009 Nov 15;34(24):2669-73. doi: 10.1097/BRS.0b013e3181b43c62.
Case series.
Evaluation of ultrasound and nerve stimulation-guided L5 nerve root block technique.
Ultrasound-guided peripheral nerve block has become clinically applied. However, selective lumbosacral nerve root block is conducted under radiographic guidance, which involves patients and operators being exposed to radiation. In addition, it cannot be carried out easily during outpatient visits or at the bedside. We conducted L5 nerve root block, which is one of the most common lumbosacral nerve root block under ultrasonic guidance, using electrical nerve stimulation.
We assessed the effectiveness of ultrasound and nerve stimulation-guided L5 nerve root block on 78 patients with L5 radicular syndrome. To compare ultrasonic guidance using electrical nerve stimulation with radiographic guidance, we used a contrast agent and assessed its distribution.
After nerve block, decreased sensation at L5 neural region and diminished/fully resolved pain was observed in all patients except for 3 in whom nerve block could not be conducted as their articular process protruded laterally. Concerning the response to stimulation, all except for these 3 felt the tapping sensation at their L5 neural regions, but no contraction of muscles was observed. The number of patients who showed an extraneural, paraneural, and intraneural pattern on contrast radiography was 71, 4, and 0, respectively.
Ultrasound-guided L5 nerve root block using electrical nerve stimulation is a safe and effective method.
病例系列。
评估超声和神经刺激引导下 L5 神经根阻滞技术。
超声引导下的外周神经阻滞已在临床上得到应用。然而,选择性腰骶神经根阻滞是在放射影像引导下进行的,这会使患者和操作人员受到辐射。此外,在门诊或床边无法轻易进行。我们使用电神经刺激进行 L5 神经根阻滞,这是超声引导下最常见的腰骶神经根阻滞之一。
我们评估了 78 例 L5 神经根综合征患者在超声和神经刺激引导下进行 L5 神经根阻滞的效果。为了比较电神经刺激的超声引导与放射影像引导,我们使用了对比剂并评估了其分布。
除 3 例因关节突向外突出而无法进行神经阻滞的患者外,所有患者的 L5 神经区域感觉减退和疼痛减轻/完全缓解。在刺激反应方面,除了这 3 例患者外,所有患者都感觉到 L5 神经区域的叩击感,但没有观察到肌肉收缩。在对比放射摄影中,出现神经外、神经旁和神经内模式的患者分别为 71 例、4 例和 0 例。
使用电神经刺激的超声引导下 L5 神经根阻滞是一种安全有效的方法。