Aortic cross-clamping during cardiac operations may injure the vessel wall and cause tissue lesions. This experimental study analyses the influence of the intravascular and external pressure and the duration of aortic cross-clamping on endothelial tissue damage. Fresh porcine aortas (n=20) were tested with intravascular pressures from 30 to 80 mmHg. The external clamp pressure, necessary to occlude the aorta, was applied by using the second cog of a commercial aortic clamp and cross-clamping was performed for 1 and 30 min. The observed pressure curves were compared to the histological findings. For occlusion of the aorta, an external pressure of at least 10-fold higher than the intravascular pressure (max. 812 mmHg) had to be applied. After 30 min of clamping, a complete endothelial destruction was observed, irrespective of intra-aortic pressure. The aortic media remained intact. After 1 min clamping, fractions of intact endothelial cells were left, ranging from 40 to 70% at different intra-aortic pressures. These results indicate that endothelial tissue lesions due to aortic cross-clamping are not avoidable, even in moderate clamp application. The duration of aortic cross-clamping but not intravascular pressure is the pivotal factor. The integrity of the aortic media can be preserved if low-force cross-clamping is achieved.

摘要

心脏手术期间的主动脉交叉钳夹可能会损伤血管壁并导致组织损伤。本实验研究分析了血管内压力、外部压力以及主动脉交叉钳夹持续时间对内皮组织损伤的影响。使用20个新鲜猪主动脉,测试血管内压力范围为30至80 mmHg。通过使用商用主动脉夹的第二个齿施加闭塞主动脉所需的外部钳夹压力,并进行1分钟和30分钟的交叉钳夹。将观察到的压力曲线与组织学结果进行比较。为了闭塞主动脉,必须施加至少比血管内压力高10倍(最大812 mmHg)的外部压力。钳夹30分钟后,无论主动脉内压力如何,均观察到内皮完全破坏。主动脉中层保持完整。钳夹1分钟后,留下了完整内皮细胞部分,在不同的主动脉内压力下,其范围为40%至70%。这些结果表明,即使在适度应用钳夹的情况下,主动脉交叉钳夹导致的内皮组织损伤也无法避免。主动脉交叉钳夹的持续时间而非血管内压力是关键因素。如果实现低力交叉钳夹,可以保留主动脉中层的完整性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验