Suppr超能文献

颈椎矢状位 T2 加权磁共振成像中的 BLADE 技术。

BLADE in sagittal T2-weighted MR imaging of the cervical spine.

机构信息

Institute of Radiology, University Medical Center Regensburg, Germany.

出版信息

AJNR Am J Neuroradiol. 2010 Apr;31(4):674-81. doi: 10.3174/ajnr.A1894. Epub 2009 Nov 26.

Abstract

BACKGROUND AND PURPOSE

Image quality and diagnostic reliability of T2-weighted MR images of the cervical spine are often impaired by several kinds of artifacts, even in cooperative patients. The aim of this study was to evaluate if BLADE sequences might solve these problems in a routine patient collective.

MATERIALS AND METHODS

TSE and BLADE sequences were compared in 60 patients for T2-weighted sagittal imaging of the cervical spine. Image sharpness, motion artifacts, truncation artifacts, metal artifacts, CSF flow phenomena, contrast of anatomic structures (vertebral body/disk, spinal cord/CSF), and diagnostic reliability of spinal cord depiction were evaluated by 2 independent readers. Another 2 readers selected the sequence they would prefer for diagnostic purposes. Statistical evaluations were performed by using the Wilcoxon and the chi(2) test; differences with P < .05 were regarded as statistically significant.

RESULTS

BLADE was significantly superior to TSE regarding image sharpness, image contrast, diagnostic reliability of spinal cord depiction, motion artifacts, CSF flow phenomena, and truncation artifacts; for metal artifacts no significant improvements were found. In 50 of 60 patients, BLADE was preferred for diagnostic purposes, and TSE was favored in 3 patients. The number of examinations that were nondiagnostic due to impaired spinal cord depiction was reduced from 12 in TSE to 3 in BLADE, and nondiagnostic examinations due to overall motion artifacts were reduced from 2 to 1.

CONCLUSIONS

Using the BLADE sequence for sagittal T2-weighted imaging of the cervical spine proved to be advantageous to reduce various kinds of artifacts.

摘要

背景与目的

即使是合作的患者,颈椎 T2 加权磁共振成像的图像质量和诊断可靠性也常常受到多种伪影的影响。本研究旨在评估 BLADE 序列是否可以解决常规患者群体中的这些问题。

材料与方法

对 60 例患者的颈椎矢状 T2 加权成像进行 TSE 和 BLADE 序列比较。由 2 位独立的读者评估图像清晰度、运动伪影、截断伪影、金属伪影、CSF 流动现象、解剖结构(椎体/椎间盘、脊髓/CSF)对比度以及脊髓描绘的诊断可靠性。另外 2 位读者选择他们更倾向于用于诊断目的的序列。采用 Wilcoxon 和卡方检验进行统计评估;差异 P <.05 被认为具有统计学意义。

结果

BLADE 在图像清晰度、图像对比度、脊髓描绘的诊断可靠性、运动伪影、CSF 流动现象和截断伪影方面明显优于 TSE;在金属伪影方面没有发现显著改善。在 60 例患者中,有 50 例患者更倾向于使用 BLADE 进行诊断,有 3 例患者更倾向于使用 TSE。由于脊髓描绘受损导致的不可诊断检查的数量从 TSE 的 12 例减少到 BLADE 的 3 例,由于整体运动伪影导致的不可诊断检查的数量从 2 例减少到 1 例。

结论

使用 BLADE 序列进行颈椎矢状 T2 加权成像可以减少各种伪影,从而具有优势。

相似文献

1
BLADE in sagittal T2-weighted MR imaging of the cervical spine.
AJNR Am J Neuroradiol. 2010 Apr;31(4):674-81. doi: 10.3174/ajnr.A1894. Epub 2009 Nov 26.
2
BLADE Sequences in Transverse T2-weighted MR Imaging of the Cervical Spine. Cut-off for Artefacts?
Rofo. 2015 May;36(2):102-8. doi: 10.1055/s-0034-1385179. Epub 2014 Sep 22.
4
BLADE sequences in transverse T2-weighted MR imaging of the cervical spine. Cut-off for Artefacts?
Rofo. 2015 Feb;187(2):102-8. doi: 10.1055/s-0034-1385179. Epub 2014 Sep 22.
6
Reduction of motion, truncation and flow artifacts using BLADE sequences in cervical spine MR imaging.
Magn Reson Imaging. 2015 Feb;33(2):194-200. doi: 10.1016/j.mri.2014.10.014. Epub 2014 Nov 24.
8
Elimination of motion, pulsatile flow and cross-talk artifacts using blade sequences in lumbar spine MR imaging.
Magn Reson Imaging. 2013 Jul;31(6):882-90. doi: 10.1016/j.mri.2013.03.006. Epub 2013 Apr 18.
9
Improvement of image quality using BLADE sequences in brain MR imaging.
Magn Reson Imaging. 2013 Feb;31(2):189-200. doi: 10.1016/j.mri.2012.08.001. Epub 2012 Sep 7.
10
Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging.
Magn Reson Imaging. 2012 Oct;30(8):1099-110. doi: 10.1016/j.mri.2012.04.001. Epub 2012 Jun 4.

引用本文的文献

2
Value of chemical shift imaging in the evaluation of neural foramen stenosis.
J Clin Orthop Trauma. 2024 Jan 9;48:102338. doi: 10.1016/j.jcot.2024.102338. eCollection 2024 Jan.
4
Comparison of deep learning-based reconstruction of PROPELLER Shoulder MRI with conventional reconstruction.
Skeletal Radiol. 2023 Aug;52(8):1545-1555. doi: 10.1007/s00256-023-04321-8. Epub 2023 Mar 21.
5
Motion-robust MR imaging of the shoulder using compressed SENSE MultiVane.
Eur J Radiol Open. 2022 Nov 5;9:100450. doi: 10.1016/j.ejro.2022.100450. eCollection 2022.
7
Magnetic Resonance Imaging in Cervical Spine Trauma: More Than Soft Tissue Illustration.
Cureus. 2022 Jan 22;14(1):e21493. doi: 10.7759/cureus.21493. eCollection 2022 Jan.
8
New frontiers in esophageal radiology.
Ann Transl Med. 2021 May;9(10):904. doi: 10.21037/atm-20-2909.
9
Comparison between 2D and 3D MEDIC for human cervical spinal cord MRI at 3T.
J Med Radiat Sci. 2021 Mar;68(1):4-12. doi: 10.1002/jmrs.433. Epub 2020 Sep 15.
10
Post-contrast T1-weighted spine 3T MRI in children using a golden-angle radial acquisition.
Neuroradiology. 2019 Mar;61(3):341-349. doi: 10.1007/s00234-019-02165-5. Epub 2019 Jan 21.

本文引用的文献

6
Depiction of the cranial nerves within the brain stem with use of PROPELLER multishot diffusion-weighted imaging.
AJNR Am J Neuroradiol. 2008 May;29(5):911-2. doi: 10.3174/ajnr.A0957. Epub 2008 Feb 7.
7
Renal T2-weighted turbo-spin-echo imaging with BLADE at 3.0 Tesla: initial experience.
J Magn Reson Imaging. 2008 Jan;27(1):148-53. doi: 10.1002/jmri.21240.
8
10
Advances in magnetic resonance neuroimaging techniques in the evaluation of neonatal encephalopathy.
Top Magn Reson Imaging. 2007 Feb;18(1):3-29. doi: 10.1097/RMR.0b013e318093e6c7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验