Department of Orthodontics, Hannover Medical School, Carl-Neuberg-Strasse 1, 30625 Hannover, Germany.
Head Face Med. 2009 Dec 15;5:27. doi: 10.1186/1746-160X-5-27.
Orthodontic treatment with fixed appliances requires - among others - the correct clinical expression of torque, which depends on the precise fitting of archwire and slot. Especially in the lingual technique torque problems become clinically more evident than in labial appliances also with respect to the vertical alignment of teeth due to different distances from the center of resistance. The purpose of the present study was to compare the preciseness of slot dimensions of different lingual bracket systems.
Three lingual bracket systems were included in the study (7th Generation and STb, Ormco, Glendora, CA, USA; Incognito, TOP-Service/3 M Unitek, Monrovia, CA, USA). Non destructive analysis of vertical slot dimensions was performed using precision pin gauges (Azurea, Belprahon, Switzerland) that were tapered in increments of 0.002 mm (0.00008 inch). The sizes of 240 incisor and canine brackets were measured per system (total: 720). Data were compared using one-way ANOVA. A p-value < 0.05 was considered statistically significant.
Average slot dimensions were 0.467 mm +/- 0.007 mm (0.0184 inch +/- 0.0003 inch) for the 7th Generation bracket system, 0.466 mm +/- 0.004 mm (0.0183 inch +/- 0.0001) inch for the STb bracket system and 0.459 mm +/- 0.004 mm (0.0181 inch +/- 0.0001) inch for the Incognito bracket system. Differences between systems were statistically significant (p < 0.05).
The analyzed bracket systems for lingual treatment exhibited significant differences in slot dimension that will clinically result in torque play. These aspects must be considered in lingual orthodontic treatment.
固定矫治器正畸治疗除其他外需要正确的临床转矩表达,这取决于弓丝和槽沟的精确适配。特别是在舌侧技术中,由于距阻力中心的距离不同,转矩问题比唇侧矫治器更明显,尤其是在牙齿的垂直排齐方面。本研究的目的是比较不同舌侧托槽系统槽沟尺寸的精确性。
本研究纳入了三种舌侧托槽系统(7 代和 STb,Ormco,Glendora,CA,USA;Incognito,TOP-Service/3M Unitek,Monrovia,CA,USA)。使用精密测针(Azurea,Belprahon,瑞士)对垂直槽沟尺寸进行非破坏性分析,测针逐渐变细,增量为 0.002mm(0.00008 英寸)。每个系统测量 240 个切牙和尖牙托槽的尺寸(共 720 个)。使用单向方差分析比较数据。p 值<0.05 被认为具有统计学意义。
7 代托槽系统的平均槽沟尺寸为 0.467mm+/-0.007mm(0.0184 英寸+/-0.0003 英寸),STb 托槽系统为 0.466mm+/-0.004mm(0.0183 英寸+/-0.0001 英寸),Incognito 托槽系统为 0.459mm+/-0.004mm(0.0181 英寸+/-0.0001 英寸)。系统间差异具有统计学意义(p<0.05)。
分析的舌侧矫治系统在槽沟尺寸上存在显著差异,这将在临床中导致转矩作用。这些方面在舌侧正畸治疗中必须考虑。