Moore Daniel B, Ben Zion Itay, Neely Daniel E, Roberts Gavin J, Sprunger Derek T, Plager David A
University of Washington School of Medicine, Seattle, Washington.
J AAPOS. 2009 Dec;13(6):551-4. doi: 10.1016/j.jaapos.2009.09.012.
To determine the accuracy of postoperative predicted refractive outcomes in surgically aphakic pediatric patients undergoing secondary intraocular lens (IOL) implantation. Comparisons were also made with other variables historically considered important in cataract surgery.
Retrospective review of 50 eyes from 35 consecutive pediatric patients (< or =18 years of age) undergoing secondary IOL implantation within the ciliary sulcus or posterior capsular bag. All cases were performed by 1 of 2 surgeons and all refractions were performed manually using the retinoscope by an experienced pediatric ophthalmologist.
The mean patient age at the time of the secondary implantation was 6.5 years of age (range, 0.58-15.04). The mean patient age at the time of the primary cataract extraction was 0.78 years (range, 0.08-5.77). For all patients, mean absolute value of prediction error was 1.64 D (SD 1.58 D). There were no significant associations between mean absolute value of prediction error and any of the variables measured including axial length, corneal mean curvature, bag or sulcus implantation, formula used, or age at primary and secondary surgery (p > 0.05).
The mean absolute value of prediction error observed in this study is consistent with previous pediatric primary and secondary IOL data in that it shows a considerable difference from that expected in adult populations. Our findings support the argument that methods currently employed to calculate IOL power may fail to accurately account for all the variations in the eyes of pediatric patients.
确定接受二期人工晶状体(IOL)植入手术的无晶状体小儿患者术后预测屈光结果的准确性。还与白内障手术中历来被认为重要的其他变量进行了比较。
回顾性分析35例连续小儿患者(≤18岁)的50只眼睛,这些患者在睫状沟或后囊袋内行二期IOL植入。所有病例均由两位外科医生中的一位完成,所有验光均由一位经验丰富的小儿眼科医生使用检眼镜手动进行。
二期植入时患者的平均年龄为6.5岁(范围0.58 - 15.04岁)。初次白内障摘除时患者的平均年龄为0.78岁(范围0.08 - 5.77岁)。所有患者预测误差的平均绝对值为1.64 D(标准差1.58 D)。预测误差的平均绝对值与所测量的任何变量之间均无显著相关性,这些变量包括眼轴长度、角膜平均曲率、囊袋或睫状沟植入、所用公式或初次及二期手术时的年龄(p>0.05)。
本研究中观察到的预测误差平均绝对值与先前小儿初次和二期IOL数据一致,表明其与成人人群预期的结果有相当大的差异。我们的研究结果支持这样的观点,即目前用于计算IOL屈光度的方法可能无法准确考虑小儿患者眼睛中的所有变化。