This article describes the development of a novel, high-performance personal aerosol sampler intended to monitor occupational air pollution, specifically, microbial constituents. This prototype sampler has a horizontally positioned conical cyclone with recirculating liquid film and an ejection supply of adsorptive liquid into the inlet nozzle. Airborne pollutants were collected in the adsorptive liquid, thus improving the survivability of microbiological aerosol samples. Experimental modules of different dimensions were first evaluated. Based on the test results, a prototype sampler was fabricated and tested. Evaluation of the collection efficiency of the prototype unit indicated a higher than 90% collection efficiency for particles > 1.0 microm. The 50% cutoff diameter was between 0.70-0.75 microm. For assessment of the sampling process effect on the collected microorganisms, Bacillus thuringiensis was tested at a concentration of about 1.0 x 10(6) cells per cm(3). The viability in the prototype sampler decreased to 78% after 60 min of operation.

摘要

这篇文章描述了一种新型高性能个人气溶胶采样器的开发,该采样器旨在监测职业空气污染,特别是微生物成分。该原型采样器具有水平放置的圆锥形气旋,带有循环液体膜和喷射供应的吸附性液体进入入口喷嘴。空气污染物被收集在吸附性液体中,从而提高了微生物气溶胶样品的存活率。首先评估了不同尺寸的实验模块。根据测试结果,制造并测试了一个原型采样器。对原型装置的收集效率进行评估,结果表明对于> 1.0 微米的颗粒,收集效率高于 90%。50%截止直径在 0.70-0.75 微米之间。为了评估采样过程对收集微生物的影响,测试了浓度约为 1.0 x 10(6)细胞/立方厘米的苏云金芽孢杆菌。在原型采样器中运行 60 分钟后,苏云金芽孢杆菌的存活率下降到 78%。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验