Department of Ophthalmology, Ruijin Hospital Affiliated Shanghai Jiaotong University, Shanghai, China.
Department of Ophthalmology, Ruijin Hospital Affiliated Shanghai Jiaotong University, 197 Ruijin No. 2 Road, 200025, Shanghai, China.
Jpn J Ophthalmol. 2009 Nov;53(6):574-579. doi: 10.1007/s10384-009-0726-z. Epub 2009 Dec 18.
To investigate the correlation between blue-on-yellow perimetry (B/YP) indices and scanning laser polarimetry with variable corneal compensation (GDx VCC) parameters in primary open-angle glaucoma (POAG) patients, and to evaluate whether the two tests can detect similar glaucomatous damage.
One eye each of 86 patients with POAG was chosen. All patients were examined with the Octopus 101 automated perimetry dG2 program using the dynamic strategy/normal method (white-onwhite perimetry, W/WP), with the dG2 program using the dynamic strategy/BY method (blue-on-yellow perimetry, B/YP), and with GDx VCC. Findings were analyzed by using Pearson's correlation analysis.
Of the 42 early glaucoma patients, 28 had both B/YP visual field loss and retinal nerve fiber layer (RNFL) defects detected by the GDx VCC measurements, and in 85.7% (24/28) of patients the regions of B/YP visual field defects corresponded to the RNFL defects detected by GDx VCC. All moderate and late glaucoma patients had both B/YP visual field loss and RNFL defects detected by GDx VCC, and in 95.5% (42/44) the regions of B/YP visual field defects corresponded to the RNFL defects detected by GDx VCC. A statistically significant correlation was found between B/YP mean sensitivity (MS) and the temporal-superior-nasal-inferior-temporal (TSNIT) average (r2>0.191, P>0.047) in the early glaucoma group, but no significant correlation was found between the W/WP indices and GDx VCC parameters. In the moderate to late glaucoma group, a low or moderate, but significant, correlation was found between B/YP MS and GDx VCC parameters (r2>0.286-0.405, P>0.001-0.01), with the most correlative parameter with B/YP MS being the TSNIT average. A low but significant correlation was also found between the B/YP mean defect (MD) and TSNIT average, superior average, inferior average, and nerve fiber indicator (NFI) (r2>0.188-0.271, P>0.013-0.044), and a low or moderate significant correlation was also found between the W/WP MS and MD and the GDx VCC parameters.
The presence of significant correlations between some B/YP indices and the GDx VCC parameters in glaucoma patients suggests that the two tests can detect similar areas and amounts of glaucomatous damage. These findings raise the possibility that both techniques can be used in clinical examinations to yield convergent data.
探讨原发性开角型青光眼(POAG)患者蓝/黄视野(B/YP)检查与扫频激光偏振光仪(GDx VCC)各参数之间的相关性,并评价两种检查方法是否能检测到类似的青光眼损害。
选择 86 例 POAG 患者的每只眼,采用 Octopus 101 全自动视野计 dG2 程序中的动态策略/正常方法(白/白视野检查,W/WP)、动态策略/BY 方法(蓝/黄视野检查,B/YP)和 GDx VCC 对所有患者进行检查。采用 Pearson 相关分析对结果进行分析。
42 例早期青光眼患者中,28 例 B/YP 视野缺损和 GDx VCC 测量的视网膜神经纤维层(RNFL)缺损均被检出,28 例患者中有 85.7%(24/28)的 B/YP 视野缺损区域与 GDx VCC 检测到的 RNFL 缺损相对应。所有中晚期青光眼患者均有 B/YP 视野缺损和 GDx VCC 检测到的 RNFL 缺损,44 例患者中有 95.5%(42/44)的 B/YP 视野缺损区域与 GDx VCC 检测到的 RNFL 缺损相对应。在早期青光眼组中,B/YP 平均敏感度(MS)与颞上-鼻上-颞下-鼻下(TSNIT)平均值之间存在统计学显著相关性(r2>0.191,P>0.047),而 W/WP 指数与 GDx VCC 参数之间无显著相关性。在中晚期青光眼组中,B/YP MS 与 GDx VCC 参数之间存在低度至中度、但显著的相关性(r2>0.286-0.405,P>0.001-0.01),与 B/YP MS 相关性最强的参数是 TSNIT 平均值。B/YP 平均缺损(MD)与 TSNIT 平均值、上平均值、下平均值和神经纤维指标(NFI)之间也存在低度但显著的相关性(r2>0.188-0.271,P>0.013-0.044),W/WP MS 和 MD 与 GDx VCC 参数之间也存在低度至中度显著相关性。
青光眼患者中 B/YP 指数与 GDx VCC 参数之间存在显著相关性,提示两种检查方法可以检测到类似的青光眼损害区域和程度。这些发现提示这两种技术都可以用于临床检查,以获得一致的数据。