Abstract

BACKGROUND AND PURPOSE

CBV is a key parameter in distinguishing penumbra from ischemic core. The purpose of this study was to compare CBV measurements acquired with standard PCT with ones obtained with C-arm CT in a canine stroke model.

MATERIALS AND METHODS

Under an institutionally approved protocol, unilateral MCA strokes were created in 10 canines. Four hours later, DWI was used to confirm the presence of an infarct. CBV maps acquired with PCT were compared with ones acquired by using C-arm CT. Three experienced observers, blinded to the technique used for acquisition, evaluated the CBV maps.

RESULTS

An ischemic stroke was achieved in 9 of the 10 animals. Areas of reduced CBV were detected in 70%-75% of the PCT studies and in 83%-87% of the C-arm CT examinations, with false-positives in 1.7% and 3.3%, respectively. False-negatives were found in 25% of the PCT and 12.2% of the C-arm CT studies. In all studies, there was a significant difference between the absolute CBV values in normal and abnormal tissue (P < .005) and no significant difference between PCT and C-arm CT CBV values in either the normal or the abnormal parenchyma (P > .05).

CONCLUSIONS

CBV measurements made with C-arm CT compare well with ones made with PCT. While further work is required both to fully validate the technique and to define its ultimate clinical value, it appears that it offers a feasible method for assessing CBV in the angiography suite.

摘要

背景与目的

脑血容量(CBV)是鉴别缺血半暗带和核心梗死区的关键参数。本研究旨在比较标准 PCT 与 C 臂 CT 在犬卒中模型中测量 CBV 的结果。

材料与方法

根据机构批准的方案,10 只犬中建立单侧 MCA 卒中。4 小时后,DWI 用于确认梗死的存在。将 PCT 获得的 CBV 图与 C 臂 CT 获得的 CBV 图进行比较。3 名经验丰富的观察者对 CBV 图进行评估,他们对采集技术不知情。

结果

10 只动物中有 9 只成功建立了缺血性卒中。70%-75%的 PCT 研究和 83%-87%的 C 臂 CT 检查发现 CBV 降低,假阳性率分别为 1.7%和 3.3%。假阴性率分别为 25%和 12.2%。在所有研究中,正常组织和异常组织的绝对 CBV 值之间存在显著差异(P <.005),正常和异常组织的 PCT 和 C 臂 CT 的 CBV 值之间无显著差异(P >.05)。

结论

C 臂 CT 测量的 CBV 值与 PCT 测量的结果相当。虽然需要进一步的工作来充分验证该技术并确定其最终的临床价值,但它似乎为在血管造影室评估 CBV 提供了一种可行的方法。

相似文献

4
C-arm CT measurement of cerebral blood volume: an experimental study in canines.C型臂CT测量脑血容量:犬类实验研究
AJNR Am J Neuroradiol. 2009 May;30(5):917-22. doi: 10.3174/ajnr.A1513. Epub 2009 Mar 19.

引用本文的文献

9
Whole brain C-arm computed tomography parenchymal blood volume measurements.全脑C型臂计算机断层扫描实质血容量测量
Interv Neuroradiol. 2016 Apr;22(2):165-75. doi: 10.1177/1591019915622168. Epub 2016 Jan 14.
10
Time density curve analysis for C-arm FDCT PBV imaging.C型臂FDCT PBV成像的时间密度曲线分析
Interv Neuroradiol. 2016 Apr;22(2):176-86. doi: 10.1177/1591019915622169. Epub 2016 Jan 14.

本文引用的文献

1
C-arm CT measurement of cerebral blood volume: an experimental study in canines.C型臂CT测量脑血容量:犬类实验研究
AJNR Am J Neuroradiol. 2009 May;30(5):917-22. doi: 10.3174/ajnr.A1513. Epub 2009 Mar 19.
8
Flat-detector computed tomography (FD-CT).平板探测器计算机断层扫描(FD-CT)。
Eur Radiol. 2007 Nov;17(11):2767-79. doi: 10.1007/s00330-007-0651-9. Epub 2007 Jun 23.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验