• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Continuous spinal anesthesia with hyperbaric bupivacaine: a dose-response analysis.

作者信息

Burgess F W, Woiwood M D, Lutz R L, Walz E J, Perkins D E

机构信息

Department of Surgery, Letterman Army Medical Center, Presidio, San Francisco, California.

出版信息

Reg Anesth. 1991 Jan-Feb;16(1):52-6.

PMID:2007107
Abstract

Continuous spinal anesthesia (CSA) with hyperbaric bupivacaine (0.75% bupivacaine in 8.25% dextrose and water) was administered to 27 adult males for transurethral endoscopic surgery. Patients were randomized to receive either 3.75, 7.5 or 10 mg hyperbaric bupivacaine in a double-blind fashion. A 20-gauge nylon catheter was inserted at the L3-4 interspace, via an 18-gauge Tuohy-Schliff needle, extending only 2 cm into the subarachnoid space. All patients were placed in the lithotomy position prior to administration of the hyperbaric bupivacaine. Sensory block was assessed by pinprick and perception of a 50-Hz tetanic stimulus at 5, 10 and 20 minutes, then every 20 minutes thereafter. Peak sensory and motor block were obtained by 20 minutes for all dose ranges. Peak sensory levels were T7.1, T5.6 and T3.9 for 3.75, 7.5 and 10 mg hyperbaric bupivacaine, respectively. Linear regression analysis demonstrated a significant correlation (r = -0.68) between peak sensory level and dose of bupivacaine. Peak sensory level as estimated by pinprick and 50-Hz tetanic stimulus showed excellent correlation (r = 0.99). The role of the subarachnoid catheter in the dispersion and distribution of bupivacaine within the subarachnoid space was studied in a model spinal canal system and compared with the distribution of bupivacaine administered via a standard 25-gauge spinal needle. No significant differences were found in the distribution of bupivacaine with either method of injection. The distribution of hyperbaric bupivacaine within the subarachnoid space appears to be related to baricity but is unrelated to administration via needle or catheter.

摘要

相似文献

1
Continuous spinal anesthesia with hyperbaric bupivacaine: a dose-response analysis.
Reg Anesth. 1991 Jan-Feb;16(1):52-6.
2
Continuous spinal anesthesia: does low-dose plain or hyperbaric bupivacaine allow the performance of hip surgery in the elderly?连续脊髓麻醉:低剂量普通或重比重布比卡因能否用于老年患者的髋关节手术?
Reg Anesth. 1993 May-Jun;18(3):170-5.
3
[The effect of the injection speed on the blockade characteristics of hyperbaric bupivacaine and tetracaine in spinal anesthesia].[注射速度对高压布比卡因和丁卡因腰麻阻滞特性的影响]
Reg Anaesth. 1989 Jul;12(4):63-8.
4
Epidural volume extension and intrathecal dose requirement: plain versus hyperbaric bupivacaine.硬膜外容积扩展与鞘内给药剂量需求:普通布比卡因与重比重布比卡因的比较
Anesth Analg. 2008 Jul;107(1):333-8. doi: 10.1213/ane.0b013e3181734436.
5
[The effect of patient positioning on the spread of sensory blockade in hyperbaric and isobaric spinal anesthesia using bupivacaine].[患者体位对使用布比卡因的高压和等压脊髓麻醉中感觉阻滞扩散的影响]
Reg Anaesth. 1990 Sep;13(7):163-7.
6
[The influence of baricity on differential blockade with 0.5% bupivacaine spinal anesthesia].[比重对0.5%布比卡因腰麻中感觉与运动阻滞分离的影响]
Masui. 2001 Sep;50(9):977-85.
7
[Isobaric and hyperbaric local anesthetic used in spinal anesthesia].[用于脊髓麻醉的等比重和高比重局部麻醉剂]
Zhong Nan Da Xue Xue Bao Yi Xue Ban. 2005 Jun;30(3):325-7.
8
A dose-response study of bupivacaine for spinal anesthesia.布比卡因用于脊髓麻醉的剂量反应研究。
Anesth Analg. 1983 Oct;62(10):931-5.
9
Comparison between hemodynamic changes after single-dose and incremental subarachnoid anesthesia.单剂量与递增剂量蛛网膜下腔麻醉后血流动力学变化的比较。
Reg Anesth. 1996 Jul-Aug;21(4):298-303.
10
The influence of epidural volume extension on spinal block with hyperbaric or plain bupivacaine for Caesarean delivery.硬膜外容积扩展对剖宫产术中高压布比卡因或普通布比卡因脊麻的影响。
Eur J Anaesthesiol. 2008 Apr;25(4):307-13. doi: 10.1017/S0265021507002670. Epub 2007 Sep 21.