Norfolk and Norwich University Hospital, Colney Lane, Norwich, UK.
Graefes Arch Clin Exp Ophthalmol. 2010 Apr;248(4):551-4. doi: 10.1007/s00417-009-1265-5.
This paper aims to highlight the potential of stereolithographic models (SLM) as a tool in orbital surgical planning, and provides four examples of their role in facilitating successful surgery.
Retrospective case series report.
Case 1: SLM facilitated a successful orbital biopsy of a deep orbital mass by allowing several practice trucut biopsies. Case 2: Complex orbital fracture-repair was facilitated by using a SLM to demonstrate post-trauma and previous post-surgical-intervention bony anatomy. Case 3: Replication of accurate orbital anatomy in a case of severe socket contracture facilitated the selection of Branemark-implant placement sites to prevent inadvertent entry into the cranial cavity. Case 4: SLM prevented unnecessary surgical intervention.
SLM are useful tools for pre-operative surgical planning, and have applications in selected complex orbital and oculoplastic cases.
本文旨在强调立体光固化模型(SLM)作为眼眶手术规划工具的潜力,并提供 4 个实例来说明其在促进手术成功方面的作用。
回顾性病例系列报告。
病例 1:SLM 通过允许多次练习切割活检,成功进行了深部眼眶肿块的眼眶活检。病例 2:使用 SLM 展示外伤后和先前手术后的骨解剖结构,从而促进了复杂眼眶骨折修复。病例 3:在严重眶窝缩窄的情况下,准确复制眼眶解剖结构,有助于选择 Brånemark 种植体放置部位,以防止意外进入颅腔。病例 4:SLM 防止了不必要的手术干预。
SLM 是术前手术规划的有用工具,并且在某些复杂的眼眶和眼整形病例中有应用。