Suppr超能文献

检测和定量分析隐形眼镜沉淀物中的泪液磷脂和胆固醇:隐形眼镜材料和护理液的影响。

Detection and quantification of tear phospholipids and cholesterol in contact lens deposits: the effect of contact lens material and lens care solution.

机构信息

School of Chemistry, University of Wollongong, Wollongong, New South Wales, Australia.

出版信息

Invest Ophthalmol Vis Sci. 2010 Jun;51(6):2843-51. doi: 10.1167/iovs.09-4609. Epub 2010 Jan 20.

Abstract

PURPOSE

To examine the deposition of tear phospholipids and cholesterol onto worn contact lenses and the effect of lens material and lens care solution.

METHODS

Lipids were extracted from tears and worn contact lenses using 2:1 chloroform:methanol and the extract washed with aqueous ammonium acetate, before analysis by electrospray ionization tandem mass spectrometry (ESI-MS/MS).

RESULTS

Twenty-three molecular lipids from the sphingomyelin (SM) and phosphatidylcholine (PC) classes were detected in tears, with total concentrations of each class determined to be 5 +/- 1 pmol/microL ( approximately 3.8 microg/mL) and 6 +/- 1 pmol/microL ( approximately 4.6 microg/mL), respectively. The profile of individual phospholipids in both of these classes was shown to be similar in contact lens deposits. Deposition of representative polar and nonpolar lipids were shown to be significantly higher on senofilcon A contact lenses, with approximately 59 ng/lens SM, 195 ng/lens PC, and 9.9 microg/lens cholesterol detected, whereas balafilcon A lens extracts contained approximately 19 ng/lens SM, 19 ng/lens PC, and 3.9 microg/lens cholesterol. Extracts from lenses disinfected and cleaned with two lens care solutions showed no significant differences in total PC and SM concentrations; however, a greater proportion of PC than SM was observed, compared with that in tears.

CONCLUSIONS

Phospholipid deposits extracted from worn contact lenses show a molecular profile similar to that in tears. The concentration of representative polar and nonpolar lipids deposited onto contact lenses is significantly affected by lens composition. There is a differential efficacy in the removal of PC and SM with lens care solutions.

摘要

目的

研究泪液磷脂和胆固醇在磨损隐形眼镜上的沉积情况,以及镜片材料和护理液的影响。

方法

采用 2:1 的氯仿/甲醇提取泪液和磨损隐形眼镜中的脂质,并用乙酸铵水溶液洗涤提取物,然后用电喷雾串联质谱(ESI-MS/MS)进行分析。

结果

在泪液中检测到神经鞘磷脂(SM)和磷脂酰胆碱(PC)类的 23 种分子脂质,每个类别的总浓度分别确定为 5 +/- 1 pmol/μL(约 3.8 μg/mL)和 6 +/- 1 pmol/μL(约 4.6 μg/mL)。这两种类别的个别磷脂的谱图在隐形眼镜沉积物中显示出相似性。代表性极性和非极性脂质的沉积量表明,在 Senofilcon A 隐形眼镜上沉积量明显更高,每副隐形眼镜的 SM 沉积量约为 59ng/副,PC 沉积量为 195ng/副,胆固醇沉积量为 9.9μg/副,而 Balafilcon A 隐形眼镜的提取液中 SM 含量约为 19ng/副,PC 含量为 19ng/副,胆固醇含量为 3.9μg/副。两种护理液消毒和清洁的隐形眼镜提取液在总 PC 和 SM 浓度上没有显著差异;然而,与泪液相比,PC 的比例大于 SM。

结论

从磨损隐形眼镜中提取的磷脂沉积物显示出与泪液相似的分子谱图。代表极性和非极性脂质的沉积量明显受镜片成分的影响。护理液对 PC 和 SM 的去除效果存在差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验