Faculty of Medicine, University of Oslo, Oslo, Norway.
J Magn Reson Imaging. 2010 Feb;31(2):416-24. doi: 10.1002/jmri.22046.
To assess image quality, vessel visualization, preliminary diagnostic properties, and interobserver variability of a novel balanced turbo field echo (b-TFE) sequence and contrast-enhanced T1 fast field echo (CE-FFE) sequence with blood pool agent (BPA).
A total of 15 healthy volunteers and six patients with ultrasound-verified proximal deep vein thrombosis (DVT) were examined from the inferior vena cava (IVC) to the proximal calf veins.
The great majority of deep veins were completely visualized on both sequences. In healthy volunteers the IVC was completely visualized in five b-TFE and 11 CE-FFE scans, and partially in seven b-TFE and four CE-FFE scans (P = 0.008). Poorest image quality was in the pelvis. Contrast-to-noise ratio (CNR) was higher on b-TFE compared to CE-FFE, with significant difference in calf images (P = 0.036). Sensitivity was 100% for proximal DVT with both methods. Specificity was 70% (CE-FFE) and 80% (b-TFE) for proximal femoral DVT; 100% in distal femoral. Interobserver reliability was kappa 1.0 (b-TFE), 0.9 (CE-FFE) for proximal, and overall poor for distal DVT.
Contrast-enhancement did not add valuable information in visualizing deep veins of the lower limbs compared to b-TFE, though the IVC was slightly better visualized. Diagnostic properties and interobserver reliability of both sequences were good for proximal DVT and poor for distal DVT.
评估新型平衡涡轮场回波(b-TFE)序列和含血池对比剂的对比增强 T1 快速场回波(CE-FFE)序列的图像质量、血管可视化、初步诊断性能和观察者间变异性。
共对 15 名健康志愿者和 6 名经超声证实的近端下肢深静脉血栓形成(DVT)患者进行了检查,从下腔静脉(IVC)到近端小腿静脉。
大多数深静脉在两种序列上均完全可见。在健康志愿者中,5 例 b-TFE 和 11 例 CE-FFE 扫描可完全显示 IVC,7 例 b-TFE 和 4 例 CE-FFE 扫描部分显示(P = 0.008)。盆腔图像质量最差。b-TFE 的对比噪声比(CNR)高于 CE-FFE,在小腿图像上差异有统计学意义(P = 0.036)。两种方法对近端 DVT 的灵敏度均为 100%。近端股 DVT 的特异性分别为 70%(CE-FFE)和 80%(b-TFE);对远端股 DVT 为 100%。观察者间的可靠性为 kappa 1.0(b-TFE),0.9(CE-FFE),对于近端 DVT 整体较差,而对于远端 DVT 整体较差。
与 b-TFE 相比,增强对比并不能为下肢深静脉的可视化提供有价值的信息,尽管 IVC 的可视化效果稍好。两种序列对近端 DVT 的诊断性能和观察者间可靠性均较好,而对远端 DVT 的诊断性能和观察者间可靠性均较差。