Lu Shin-Tsu, D'Andrea John, Chalfin Steven, Crane Carrie, Marchello Donald, Garay Robert, Hatcher Donald, Ziriax John
Henry M. Jackson Foundation for the Advancement of Military Medicine, Brooks City-Base, Texas 78235-5365, USA.
Bioelectromagnetics. 2010 May;31(4):324-33. doi: 10.1002/bem.20556.
Microwave-induced corneal endothelial damage was reported to have a low threshold (2.6 W/kg), and vasoactive ophthalmologic medications lowered the threshold by a factor of 10-0.26 W/kg. In an attempt to confirm these observations, four adult male Rhesus monkeys (Macaca mulatta) under propofol anesthesia were exposed to pulsed microwaves in the far field of a 2.8 GHz signal (1.43 +/- 0.06 micros pulse width, 34 Hz pulse repetition frequency, 13.0 mW/cm(2) spatial and temporal average, and 464 W/cm(2) spatial and temporal peak (291 W/cm(2) square wave equivalent) power densities). Corneal-specific absorption rate was 5.07 W/kg (0.39 W/kg/mW/cm(2)). The exposure resulted in a 1.0-1.2 degrees C increase in eyelid temperature. In Experiment I, exposures were 4 h/day, 3 days/week for 3 weeks (nine exposures and 36 h total). In Experiment II, these subjects were pretreated with 0.5% Timolol maleate and 0.005% Xalatan(R) followed by 3 or 7 4-h pulsed microwave exposures. Under ketamine-xylazine anesthesia, a non-contact specular microscope was used to obtain corneal endothelium images, corneal endothelial cell density, and pachymetry at the center and four peripheral areas of the cornea. Ophthalmologic measurements were done before and 7, 30, 90, and 180 days after exposures. Pulsed microwave exposure did not cause alterations in corneal endothelial cell density and corneal thickness with or without ophthalmologic drugs. Therefore, previously reported changes in the cornea exposed to pulsed microwaves were not confirmed at exposure levels that are more than an order of magnitude higher.
据报道,微波诱导的角膜内皮损伤阈值较低(2.6 W/kg),而血管活性眼科药物可将该阈值降低至0.26 W/kg(降低了10倍)。为了证实这些观察结果,对4只在丙泊酚麻醉下的成年雄性恒河猴(猕猴)进行了实验,使其暴露于2.8 GHz信号远场中的脉冲微波下(脉冲宽度为1.43±0.06微秒,脉冲重复频率为34 Hz,空间和时间平均功率密度为13.0 mW/cm²,空间和时间峰值功率密度为464 W/cm²(等效方波为291 W/cm²))。角膜比吸收率为5.07 W/kg(0.39 W/kg/mW/cm²)。暴露导致眼睑温度升高1.0 - 1.2℃。在实验I中,暴露时间为每天4小时,每周3天,共3周(9次暴露,总计36小时)。在实验II中,这些受试动物先用0.5%马来酸噻吗洛尔和0.005%适利达预处理,然后进行3次或7次4小时的脉冲微波暴露。在氯胺酮 - 赛拉嗪麻醉下,使用非接触式角膜内皮显微镜获取角膜中央和四个周边区域的角膜内皮图像、角膜内皮细胞密度和角膜厚度测量值。在暴露前以及暴露后7天、30天、90天和180天进行眼科测量。无论有无眼科药物,脉冲微波暴露均未引起角膜内皮细胞密度和角膜厚度的改变。因此,在高于先前报道水平一个数量级以上的暴露水平下,未证实先前报道的脉冲微波暴露引起的角膜变化。