关于扇形束厚度在鼻咽癌螺旋断层放射治疗中作用的病例报告。

A case report on the effect of fan beam thickness in helical tomotherapy of nasopharyngeal carcinoma.

作者信息

Wu W C Vincent, Mui Wing Lun A

机构信息

Department of Health Technology and Informatics, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong.

出版信息

Med Dosim. 2011 Spring;36(1):57-61. doi: 10.1016/j.meddos.2009.11.004. Epub 2010 Feb 4.

Abstract

The fan beam thickness (FBT) in helical tomotherapy is defined by a pair of collimators parallel to the rotational orbit of the radiation beam and is fixed for a specific patient treatment. The aim of this case study is to evaluate the dosimetric influence of changing the FBT in the treatment of a nasopharyngeal carcinoma (NPC) patient. The subject was a T2N1M0 stage NPC patient. The planning target volumes (PTVs) of the primary nasopharyngeal tumor and the left and right cervical lymphatics were delineated along with the organs at risk (OARs) in the corresponding computed tomography slices. Three treatment plans with FBT of 1.0 cm, 2.5 cm, and 5.0 cm (FBT-10, FBT-25, and FBT-50) were generated separately based on similar dose constraints and planning parameters. The dosimetric results of the PTV and OARs were collected and compared among the 3 treatment plans. The differences in the dose parameters of the PTVs were small among the 3 plans. The FBT-10 plan demonstrated the most homogeneous PTV doses with the smallest homogeneity indices (HIs). The FBT-50 plan delivered the highest dose to the OARs and the FBT-10 plan delivered the lowest. The differences between the 2 plans were more significant in the spinal cord, optic chiasm, optic nerves, and lens. This case study demonstrated that the variation of FBT in tomotherapy affected the quality of the treatment plan mainly in the OAR doses, but not so much in the PTV. Increasing the FBT reduced the effectiveness in the sparing of OARs.

摘要

螺旋断层放射治疗中的扇形束厚度(FBT)由一对平行于辐射束旋转轨道的准直器定义,并且对于特定患者的治疗是固定的。本病例研究的目的是评估在鼻咽癌(NPC)患者治疗中改变FBT的剂量学影响。该受试者为一名T2N1M0期NPC患者。在相应的计算机断层扫描切片中,勾画出了鼻咽原发肿瘤以及左右颈部淋巴结的计划靶区(PTV)和危及器官(OAR)。基于相似的剂量限制和计划参数,分别生成了扇形束厚度为1.0厘米、2.5厘米和5.0厘米的三个治疗计划(FBT-10、FBT-25和FBT-50)。收集并比较了这三个治疗计划中PTV和OAR的剂量学结果。三个计划中PTV的剂量参数差异较小。FBT-10计划显示PTV剂量最均匀,均匀性指数(HI)最小。FBT-50计划给予OAR的剂量最高,而FBT-10计划给予的剂量最低。这两个计划在脊髓、视交叉、视神经和晶状体方面的差异更为显著。本病例研究表明,断层放射治疗中FBT的变化主要在OAR剂量方面影响治疗计划的质量,而对PTV的影响较小。增加FBT会降低对OAR的保护效果。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验