Suppr超能文献

Flexi-bar 与假 Flexi-bar 运动对肌肉肌电图活动和性能的急性影响。

Acute effects of Flexi-bar vs. Sham-bar exercise on muscle electromyography activity and performance.

机构信息

Sport and Exercise Science Research Center, Academy of Sport, FESBE, London South Bank University, London, United Kingdom.

出版信息

J Strength Cond Res. 2010 Mar;24(3):737-48. doi: 10.1519/JSC.0b013e3181c7c2d8.

Abstract

This study was conducted to investigate whether the low-frequency (5-Hz) oscillatory vibration-like stimulus, purported to be delivered by exercising with Flexi-bar, acutely affects muscle activation and maximal voluntary contraction (MVC) force. Nine healthy men participated in 2 trials, separated by at least 1 week, during which 4 x 30-second sets of exercise were performed with either the Flexi bar or a Sham bar. Maximal voluntary contraction force for elbow flexion, elbow extension, and knee extension were measured before and after the exercise. Root-mean-square amplitude and median frequency of electromyography (EMG) signal were calculated for the first and last 10 seconds of each exercise set and during the MVCs from biceps brachii (BB), triceps brachii (TB), rectus femoris (RF), and vastus lateralis (VL) for each trial. Electromyography amplitude was significantly higher for all studied muscles during Flexi-bar than Sham-bar exercise (32-203%, p < 0.05). Median frequency of EMG power spectrum was significantly lower in arm (TB: -40 +/- 13%, p < 0.0001; BB: -32 +/- 25%, p = 0.015) but not in leg (RF: -12 +/- 18%; VL: +6 +/- 32%; p > 0.05) muscles during Flexi-bar compared with Sham-bar exercise. Knee extension MVC force significantly decreased after Flexi-bar exercise (-3 +/- 7%, p = 0.048) in parallel with reduced RF EMG amplitude (-8 +/- 5%, p = 0.04), but there were no acute residual effects on elbow flexion/extension MVC or arm and VL EMG muscle activity. Using Flexi bar during exercise provoked acute alterations in arm- and leg-muscle EMG parameters and maximum force-generating capacity, indicating greater fatigue development than when exercising with the Sham bar. The results of this study indicate that Flexi bar may therefore be used to impose a stronger training stimulus on the muscle during submaximal exercise.

摘要

本研究旨在探讨低频(5Hz)振动样刺激是否会对肌肉激活和最大自主收缩(MVC)力产生急性影响,这种刺激据称是通过 Flexi-bar 运动产生的。9 名健康男性参加了 2 项试验,每项试验之间至少间隔 1 周,在这 2 项试验中,他们分别使用 Flexi 棒和假 Flexi 棒进行 4 组 30 秒的运动。在运动前后测量了肘屈肌、肘伸肌和伸膝肌的最大自主收缩力。计算了每组运动的前 10 秒和最后 10 秒以及每次试验中肱二头肌(BB)、肱三头肌(TB)、股直肌(RF)和股外侧肌(VL)的 MVC 时的肌电图(EMG)信号的均方根振幅和中值频率。在 Flexi 棒运动时,所有研究肌肉的 EMG 振幅均显著高于假 Flexi 棒运动(32-203%,p<0.05)。与假 Flexi 棒运动相比,在 Flexi 棒运动时,手臂(TB:-40±13%,p<0.0001;BB:-32±25%,p=0.015)而非腿部(RF:-12±18%;VL:+6±32%;p>0.05)肌肉的 EMG 功率谱中值频率显著降低。与 RF EMG 振幅降低(-8±5%,p=0.04)一致,Flexi 棒运动后伸膝 MVC 力显著下降(-3±7%,p=0.048),但对肘屈/伸 MVC 或手臂和 VL EMG 肌肉活动没有急性残留影响。在运动中使用 Flexi 棒会引起手臂和腿部肌肉 EMG 参数和最大力量产生能力的急性变化,表明与使用假 Flexi 棒相比,疲劳发展更为严重。本研究结果表明,因此,在亚最大运动中,Flexi 棒可用于对肌肉施加更强的训练刺激。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验