Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan.
Lett Appl Microbiol. 2010 Apr;50(4):386-92. doi: 10.1111/j.1472-765X.2010.02806.x. Epub 2010 Jan 22.
To develop a detection assay for staphylococcal mecA and spa by using loop-mediated isothermal amplification (LAMP) method.
Staphylococcus aureus and other related species were subjected to the detection of mecA and spa by both PCR and LAMP methods. The LAMP successfully amplified the genes under isothermal conditions at 64 degrees C within 60 min, and demonstrated identical results with the conventional PCR methods. The detection limits of the LAMP for mecA and spa, by gel electrophoresis, were 10(2) and 10 cells per tube, respectively. The naked-eye inspections were possible with 10(3) and 10 cells for detection of mecA and spa, respectively. The LAMP method was then applied to sputum and dental plaque samples. The LAMP and PCR demonstrated identical results for the plaque samples, although frequency in detection of mecA and spa by the LAMP was relatively lower for the sputum samples when compared to the PCR methods.
Application of the LAMP enabled a rapid detection assay for mecA and spa. The assay may be applicable to clinical plaque samples.
The LAMP offers an alternative detection assay for mecA and spa with a great advantage of the rapidity.
建立一种利用环介导等温扩增(LAMP)方法检测葡萄球菌 mecA 和 spa 的检测方法。
采用 PCR 和 LAMP 方法对金黄色葡萄球菌和其他相关物种进行 mecA 和 spa 的检测。LAMP 能够在 64°C 下等温条件下 60 分钟内成功扩增基因,并与常规 PCR 方法产生相同的结果。LAMP 对 mecA 和 spa 的检测限通过凝胶电泳分别为 10(2)和 10 个细胞/管。通过肉眼观察,mecA 和 spa 的检测限分别为 10(3)和 10 个细胞。然后将 LAMP 方法应用于痰和牙菌斑样本。LAMP 和 PCR 对牙菌斑样本的检测结果相同,尽管与 PCR 方法相比,LAMP 检测痰样本中 mecA 和 spa 的频率相对较低。
LAMP 可用于快速检测 mecA 和 spa。该检测方法可能适用于临床牙菌斑样本。
LAMP 为 mecA 和 spa 提供了一种替代的检测方法,具有快速的优势。