The present study aimed to assess the dosing accuracy of commonly used disposable insulin pens including SoloStar (SR)*, FlexPen (FP) dagger, Next Generation FlexPen (NGFP) dagger, and KwikPen (KP) double dagger. It is the first comparative study covering the whole dosing range from 1 U to 60 U. It also covers the accuracy of SR at 80 U.
A total of sixty insulin pens from two lots of each pen type were used. From each pen 1 U, 10 U, 30 U, 40 U, 60 U and 80 U were dispensed in random order. The 80 U dose was only evaluated for the SR as the other insulin pens do not deliver this dose in one injection. The actual doses were determined gravimetrically taking density of the different insulin preparations into account. The evaluation of dose accuracy was based on the regulations of the International Organization for Standardization (DIN EN ISO 11608-1:2000).
All tested insulin pens met the requirements for accuracy with none of the single values at all dose levels being outside the defined range of the ISO recommendations (1 +/- 1 U, 10 +/- 1 U, 30 +/- 1.5 U, 40 +/- 2 U, 60 +/- 3 U and 80 +/- 4 U). For the investigated dosage levels the absolute average deviation of all insulin pens ranged between 0.09 and 0.81 U.
The present study demonstrates an excellent dosing accuracy for all tested insulin pens, with no clinically relevant differences between the products.
本研究旨在评估常用一次性胰岛素笔,包括 SoloStar(SR)*、FlexPen(FP)匕首、下一代 FlexPen(NGFP)匕首和 KwikPen(KP)双匕首的剂量准确性。这是第一项涵盖从 1U 到 60U 整个剂量范围的比较研究。它还涵盖了 SR 在 80U 时的准确性。
使用来自两种笔型的各 60 支胰岛素笔。从每支笔中以随机顺序分配 1U、10U、30U、40U、60U 和 80U。仅对 SR 评估 80U 剂量,因为其他胰岛素笔无法在一次注射中提供此剂量。实际剂量通过考虑不同胰岛素制剂的密度进行称重确定。剂量准确性的评估基于国际标准化组织(DIN EN ISO 11608-1:2000)的规定。
所有测试的胰岛素笔均符合准确性要求,所有剂量水平的单个值均未超出 ISO 建议规定的范围(1 +/- 1U、10 +/- 1U、30 +/- 1.5U、40 +/- 2U、60 +/- 3U 和 80 +/- 4U)。对于所研究的剂量水平,所有胰岛素笔的绝对平均偏差在 0.09 到 0.81U 之间。
本研究表明,所有测试的胰岛素笔均具有出色的剂量准确性,产品之间没有临床相关差异。