Suppr超能文献

使用波前传感器和光学相干断层扫描同时测量泪膜动力学。

Simultaneous measurement of tear film dynamics using wavefront sensor and optical coherence tomography.

机构信息

Eye Institute, University of Rochester, Rochester, New York, USA.

出版信息

Invest Ophthalmol Vis Sci. 2010 Jul;51(7):3441-8. doi: 10.1167/iovs.09-4430. Epub 2010 Feb 17.

Abstract

PURPOSE. To investigate tear film dynamics using simultaneous measurements of ocular aberrations and lower tear meniscus. METHODS. Simultaneous measurements of wavefront aberration and lower tear meniscus were performed for 11 normal eyes and 7 eyes with short tear film break-up time (SBUT) dry eye, with a tear film break-up time shorter than 5 seconds, using a wavefront sensor and an anterior segment optical coherence tomography (OCT). During the measurement, the subjects were instructed to blink every 6 seconds for a total of 30 seconds. From the measured aberration, root mean square (RMS) wavefront error and volume modulation transfer function (vMTF) induced by changes in tear film dynamics were calculated for a 5-mm pupil. Lower tear meniscus height (TMH) and area (TMA) were estimated from the cross-sectional OCT images of lower tear meniscus. RESULTS. There was a positive correlation between RMS and tear meniscus dimensions and a negative correlation between vMTF and tear meniscus in both groups. There were moderate negative correlations between the postblink initial RMS change and baseline TMH (R = -0.61) and TMA (R = -0.54) in SBUT dry eyes that were stronger than in normal eyes (R = -0.37, R = -0.38). CONCLUSIONS. Tear meniscus dimensions increase with RMS over time, and tear quantity before blink has a significant role in maintaining initial optical integrity, especially in SBUT dry eye. Simultaneous measurement of optical quality and tear meniscus has the potential to improve understanding of tear stability in normal eyes and dry eyes.

摘要

目的。使用眼像差和下泪膜弯月面的同步测量来研究泪膜动力学。

方法。使用波前传感器和眼前段光学相干断层扫描(OCT)对 11 只正常眼和 7 只泪膜破裂时间(SBUT)较短的干眼(眨眼后泪膜破裂时间小于 5 秒)进行眼像差和下泪膜弯月面的同步测量。在测量过程中,要求受试者每 6 秒眨眼一次,共 30 秒。从测量的像差中,计算出 5mm 瞳孔下 RMS 波前像差和由泪膜动力学变化引起的体积调制传递函数(vMTF)。从下泪膜弯月面的 OCT 横截面图像中估算下泪膜弯月面高度(TMH)和面积(TMA)。

结果。在两组中,RMS 与泪膜弯月面的尺寸呈正相关,vMTF 与泪膜弯月面呈负相关。在 SBUT 干眼症中,眨眼后初始 RMS 变化与基线 TMH(R=-0.61)和 TMA(R=-0.54)之间存在中度负相关,比正常眼更强(R=-0.37,R=-0.38)。

结论。随着时间的推移,泪膜弯月面的尺寸与 RMS 呈正相关,眨眼前的泪液量在保持初始光学完整性方面起着重要作用,尤其是在 SBUT 干眼症中。光学质量和泪膜弯月面的同步测量有潜力改善对正常眼和干眼症中泪液稳定性的理解。