Suppr超能文献

一项关于测量主动和被动颈椎活动范围方法的可靠性和有效性研究的系统评价。

A systematic review of reliability and validity studies of methods for measuring active and passive cervical range of motion.

作者信息

Williams Mark A, McCarthy Christopher J, Chorti Angeliki, Cooke Matthew W, Gates Simon

机构信息

Clinical Trials Unit, University of Warwick, Coventry, United Kingdom.

出版信息

J Manipulative Physiol Ther. 2010 Feb;33(2):138-55. doi: 10.1016/j.jmpt.2009.12.009.

Abstract

OBJECTIVE

The purpose of this study was to systematically review the literature evaluating the reliability and validity of all available methods for measuring active and passive cervical range of motion (CROM).

METHODS

Electronic databases (PubMed, MEDLINE, CINAHL, EMBASE, and AMED) were searched through OVID from their inception to January 2008. Articles were selected according to a priori defined criteria. Data were extracted regarding publication details, type of study, movements and device evaluated, subject and observer characteristics, and measurement protocol including blinding and statistical analysis methods. Quality assessment was undertaken using developed criteria to assess internal validity, external validity, and statistical methods. An estimate of the level of reliability and validity was calculated and used to categorize studies as good, moderate, or poor.

RESULTS

A total of 56 articles fulfilled the selection criteria and were included in the review. Forty-six of these articles described 66 reliability studies and 21 described 21 concurrent criterion validity studies. Twelve different methods were evaluated. Although it was the intention of this review to conduct meta-analysis, this was deemed inappropriate due to studies being too heterogeneous. Most of the reliability and validity studies involved asymptomatic subjects measured by allied health professionals investigating active ROM. Devices that were deemed to have "good" reliability and validity were the CROM device, the Spin-T goniometer, and the single inclinometer.

CONCLUSIONS

A considerable number of reliability and concurrent validity studies have been published for CROM. The CROM device has undergone most evaluation and has been shown to be clinimetrically sound. Further research with significantly improved methodology and reporting is warranted for all devices.

摘要

目的

本研究旨在系统回顾文献,评估所有可用于测量颈椎主动和被动活动范围(CROM)的方法的可靠性和有效性。

方法

通过OVID检索电子数据库(PubMed、MEDLINE、CINAHL、EMBASE和AMED),检索时间从各数据库建库起至2008年1月。根据预先定义的标准选择文章。提取有关出版细节、研究类型、评估的运动和设备、受试者和观察者特征以及测量方案(包括盲法和统计分析方法)的数据。使用制定的标准进行质量评估,以评估内部有效性、外部有效性和统计方法。计算可靠性和有效性水平的估计值,并用于将研究分为良好、中等或较差。

结果

共有56篇文章符合选择标准并纳入本综述。其中46篇文章描述了66项可靠性研究,21篇文章描述了21项同时效度研究。评估了12种不同的方法。尽管本综述旨在进行荟萃分析,但由于研究的异质性过高,认为不适合进行。大多数可靠性和有效性研究涉及由专职医疗人员测量无症状受试者的主动活动范围。被认为具有“良好”可靠性和有效性的设备是CROM设备、旋转T型测角仪和单倾角仪。

结论

已发表了大量关于CROM的可靠性和同时效度研究。CROM设备接受的评估最多,并且已证明在临床测量方面是可靠的。所有设备都需要采用显著改进的方法和报告方式进行进一步研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验