Abstract

BACKGROUND

The biological problems related to wear debris after total hip arthroplasty have stimulated renewed interest in alternatives to metal-on-polyethylene bearing surfaces.

METHODS

We retrospectively evaluated the clinical and radiographic results of 100 patients who had undergone a total of 109 primary total hip arthroplasties with a cementless alumina ceramic-on-ceramic prosthesis between January 1985 and December 1989. The mean age of the patients at the time of the index arthroplasty was forty-six years. Clinical evaluation was performed with use of the Charnley modification of the Merle d'Aubigné-Postel scale. Seventy-eight patients who had had a total of eighty-five arthroplasties were available for follow-up evaluation at an average of 20.8 years. The patients' average age at the time of the latest follow-up was 66.8 years.

RESULTS

Six hips (six acetabular cups and one femoral stem) in six patients underwent revision. Aseptic loosening of the cup combined with focal osteolysis was the cause of all six revisions. In one patient, the stem was also revised because of aseptic loosening. At the time of final follow-up, the result was excellent (according to the Merle d'Aubigné-Postel scale) in 68% of the hips, good in 19%, fair in 9%, and poor in 4%. The mean Merle d'Aubigné-Postel score improved from 7.9 points preoperatively to 16.9 points postoperatively (p < 0.001). The cumulative rate of survival of the prostheses was 84.4% at 20.8 years.

CONCLUSIONS

The results of these cementless ceramic-on-ceramic total hip arthroplasties continued to be satisfactory at a minimum of twenty years postoperatively. The improved design of contemporary prostheses and the new generation of ceramic-on-ceramic bearing surfaces may lead to even better long-term results.

摘要

背景

全髋关节置换术后与磨损颗粒相关的生物学问题再次激发了人们对金属-聚乙烯关节面替代物的兴趣。

方法

我们回顾性评估了 1985 年 1 月至 1989 年 12 月期间使用无水泥氧化铝陶瓷-陶瓷假体进行的 109 例初次全髋关节置换术的 100 例患者的临床和影像学结果。患者在指数关节置换时的平均年龄为 46 岁。临床评估采用 Charnley 改良的 Merle d'Aubigné-Postel 评分。78 例患者(85 例髋关节)在平均 20.8 年时可进行随访评估。患者在最后一次随访时的平均年龄为 66.8 岁。

结果

6 例(6 个髋臼杯和 1 个股骨柄)中有 6 例髋关节需要翻修。所有 6 例翻修的原因均为髋臼杯无菌性松动伴局灶性骨溶解。在 1 例患者中,由于无菌性松动,还对股骨柄进行了翻修。最终随访时,68%的髋关节疗效为优(根据 Merle d'Aubigné-Postel 评分),19%为良,9%为可,4%为差。Merle d'Aubigné-Postel 评分从术前的 7.9 分提高到术后的 16.9 分(p<0.001)。20.8 年后,假体的累积生存率为 84.4%。

结论

这些无水泥陶瓷-陶瓷全髋关节置换术的结果在术后至少 20 年仍保持满意。当代假体的改进设计和新一代陶瓷-陶瓷关节面可能会带来更好的长期效果。