Suppr超能文献

氧化铝对氧化铝全髋关节置换术。一项至少随访五年的研究。

Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.

作者信息

Yoo Jeong Joon, Kim Young-Min, Yoon Kang Sup, Koo Kyung-Hoi, Song Won Seok, Kim Hee Joong

机构信息

Department of Orthopaedic Surgery, Seoul National University Hospital, 28 Yongondong, Chongnogu, 110-744, Seoul, Korea.

出版信息

J Bone Joint Surg Am. 2005 Mar;87(3):530-5. doi: 10.2106/JBJS.D.01753.

Abstract

BACKGROUND

Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contemporary alumina-on-alumina total hip arthroplasties with regard to wear, osteolysis, and fracture of the ceramic after a minimum duration of follow-up of five years.

METHODS

We evaluated the results of a consecutive series of 100 primary alumina-on-alumina total hip arthroplasties that had been performed with use of a metal-backed socket and a cementless stem in eighty-four patients. All of the patients were sixty-five years of age or younger (mean age, forty-one years), and a single surgeon performed all of the procedures. After a minimum duration of follow-up of sixty months, one patient (one hip) had died and four patients (six hips) had been lost to follow-up, leaving a total of seventy-nine patients (ninety-three hips) available for study. All of these patients were evaluated clinically and radiographically with special attention to wear, periprosthetic osteolysis, and ceramic failure.

RESULTS

The mean Harris hip score was 97 points at the time of the latest follow-up evaluation. All prostheses demonstrated radiographic evidence of bone ingrowth. No implant was loose radiographically, and no implant was revised. Ceramic wear was not detectable in the thirty-seven hips in which the femoral head could be differentiated from the cup on radiographs. Periprosthetic osteolysis was not observed in any hip. A fracture of the alumina femoral head and a peripheral chip fracture of the alumina insert occurred in one hip following a motor-vehicle accident.

CONCLUSIONS

The results of contemporary alumina-on-alumina total hip arthroplasty with a metal-backed socket and a cementless stem were encouraging after a minimum duration of follow-up of five years. We believe that these improved alumina-on-alumina bearing implants offer a promising option for younger, active patients.

摘要

背景

陶瓷对陶瓷关节是有吸引力的替代承重表面,据报道可消除或减少与聚乙烯磨损颗粒相关的问题。过去氧化铝陶瓷轴承令人失望的使用经历促使陶瓷植入物的制造和设计有了许多改进。本研究的目的是报告在至少随访五年后,当代氧化铝对氧化铝全髋关节置换术在磨损、骨溶解和陶瓷骨折方面的结果。

方法

我们评估了连续100例初次氧化铝对氧化铝全髋关节置换术的结果,这些手术在84例患者中使用了金属背衬髋臼杯和非骨水泥股骨柄。所有患者年龄均在65岁及以下(平均年龄41岁),且所有手术均由同一位外科医生完成。在至少随访60个月后,1例患者(1髋)死亡,4例患者(6髋)失访,共有79例患者(93髋)可供研究。所有这些患者均接受了临床和影像学评估,特别关注磨损、假体周围骨溶解和陶瓷失效情况。

结果

在最近一次随访评估时,Harris髋关节平均评分为97分。所有假体均显示有骨长入的影像学证据。影像学上无植入物松动,也无植入物翻修情况。在37例髋关节中,通过X线片可区分股骨头与髋臼杯,未检测到陶瓷磨损。任何髋关节均未观察到假体周围骨溶解。1例髋关节在机动车事故后发生了氧化铝股骨头骨折和氧化铝内衬的周边碎片骨折。

结论

在至少随访五年后,当代使用金属背衬髋臼杯和非骨水泥股骨柄的氧化铝对氧化铝全髋关节置换术的结果令人鼓舞。我们认为,这些改良的氧化铝对氧化铝承重植入物为年轻、活跃的患者提供了一个有前景的选择。