Abstract

Atrial septal defect transcatheter occlusion techniques have become an alternative to surgical procedures. With the increasing use of this new technology, several complications have been identified. The authors present the case of a patient who was admitted to the hospital for primary percutaneous closure of a secundum atrial septal defect. On routine follow-up examination 24 hours after implantation, transthoracic echocardiography revealed a partial dislocation of the occluder into the right atrium. The patient was referred for cardiosurgical treatment. Strict selection criteria and the choice of the device may help reduce the incidence of complications such as dislocation of the occluder into the right atrium following the percutaneous device closure of an atrial septal defect.

摘要

房间隔缺损经导管封堵技术已成为手术治疗的一种替代方法。随着这项新技术的应用越来越广泛,已经发现了几种并发症。作者报告了一例患者,该患者因继发孔房间隔缺损的经皮闭合术入院。在植入后 24 小时的常规随访检查中,经胸超声心动图显示封堵器部分脱位至右心房。患者被转诊接受心脏手术治疗。严格的选择标准和器械的选择可能有助于减少经皮器械封堵房间隔缺损后封堵器脱位至右心房等并发症的发生率。