Bowman K F, Monteiro-Riviere N A, Riviere J E
Laboratory of Surgical Research, College of Veterinary Medicine, North Carolina State University, Raleigh 27606.
Am J Vet Res. 1991 Jan;52(1):75-82.
We developed a single-pedicle, axial pattern tubed skin flap that could be transferred to an in vitro perfusion apparatus. On the basis of results of prosections, angiography, contact radiography, and surviving-length studies, it was concluded that a single-pedicle, axial pattern skin flap measuring 4 cm x 12 cm incorporating the caudal superficial epigastric artery would survive to its entire length. Subsequently, a surgical (stage 1) procedure was developed for the routine preparation of single-pedicle, axial pattern tubed skin flaps. Healing after the stage-1 procedure was evaluated by visual inspection and fluorescein angiography. Stage-1 procedures were performed successfully 149 of 160 (93%) times. A second surgical (stage 2) procedure was developed for routine cannulation of the caudal superficial epigastric artery and harvest of the tubed skin flap. Stage-2 procedures were performed successfully 136 of 144 (94%) times.
我们开发了一种单蒂轴型管状皮瓣,可将其转移至体外灌注装置。根据解剖标本、血管造影、接触式X线摄影及存活长度研究结果,得出结论:包含腹壁浅动脉尾侧支的4厘米×12厘米单蒂轴型皮瓣可全长存活。随后,制定了一种外科手术(第1阶段)程序,用于单蒂轴型管状皮瓣的常规制备。通过目视检查和荧光素血管造影评估第1阶段手术后的愈合情况。160例中有149例(93%)第1阶段手术成功实施。制定了第二种外科手术(第2阶段)程序,用于腹壁浅动脉尾侧支的常规插管及管状皮瓣的切取。144例中有136例(94%)第2阶段手术成功实施。