Capillary isotachophoresis with coupled columns provides efficient means for rapid electrophoretic analysis of sample volumes of up to 10microl or more. Commercially available instruments are commonly equipped with conductivity and UV absorbance detectors; however, their on-line coupling with electrospray mass spectrometry is highly desirable. In this work we have modified the commercial coupled column isotachophoresis system for direct connection to an ion trap mass spectrometer. The design included attachment of an elution block with a short capillary transfer line directing the separated zones towards the mass spectrometer. The modification further included separation of the injection and electrode blocks from the separation columns by semipermeable membranes eliminating unwanted fluid movements in the wide bore fluoropolymer separation capillaries. Fused silica capillaries with varying internal diameter were connected as a transfer line between the elution block and mass spectrometer. The transfer line served also as the ESI tip of the sheathless electrospray interface. During the analysis the first, wide bore preseparation capillary with 0.8mm internal diameter served for removal of the bulk sample components and preseparation of the potentially interfering analytes. After the electronic column switching the separation was finished in a 0.3mm internal diameter capillary and the separated ITP zones were transferred in-line by a spray liquid towards the mass spectrometer. The instrumentation was tested for determination of vitamins in whole blood analysis and separation of tryptic peptides.
毛细管等速电泳与耦合柱联用为快速电泳分析提供了有效的手段,样品体积可达 10μL 或更多。市售仪器通常配备有电导和紫外吸收检测器;然而,将其与电喷雾质谱在线耦合是非常需要的。在这项工作中,我们对商业耦合柱等速电泳系统进行了修改,以直接连接到离子阱质谱仪。设计包括安装带有短毛细管转移线的洗脱块,将分离区域引导至质谱仪。该改进进一步通过半透膜将注入和电极块与分离柱分离,消除了宽口径氟聚合物分离毛细管中不必要的流体运动。不同内径的熔融石英毛细管作为洗脱块和质谱仪之间的转移线连接。转移线还作为无鞘电喷雾接口的 ESI 尖端。在分析过程中,内径为 0.8mm 的第一根宽口径预分离毛细管用于去除大量样品成分和预分离潜在干扰的分析物。在电子柱切换后,分离在 0.3mm 内径的毛细管中完成,分离的 ITP 区通过喷雾液体在线转移到质谱仪。该仪器已用于全血分析中维生素的测定和胰蛋白酶肽的分离。