Scintillation proximity assay (SPA), which does not require the physical separation of bound and free hormone, was applied to the determination of cortisol in plasma. Results showed excellent agreement with a conventional radioimmunoassay using dextran-coated charcoal to separate bound and free cortisol, with similar precision and sensitivity. When the SPA was applied to the measurement of plasma aldosterone, it was evident from the SPA and radioimmunoassay results that the blocking of aldosterone binding to corticosteroid-binding globulin by 8-amino-1-naphthalene-sulphonic acid was not completely effective, and that a different sample preparation technique should be used. SPA may become the method of choice for the determination of hormones in blood.

摘要

闪烁邻近分析法(SPA)无需对结合态和游离态激素进行物理分离,已应用于血浆皮质醇的测定。结果显示,该方法与使用葡聚糖包被活性炭分离结合态和游离态皮质醇的传统放射免疫分析法结果高度一致,具有相似的精密度和灵敏度。当将SPA应用于血浆醛固酮的测定时,从SPA和放射免疫分析法结果可以明显看出,8-氨基-1-萘磺酸对醛固酮与皮质类固醇结合球蛋白结合的阻断并不完全有效,因此应采用不同的样品制备技术。SPA可能会成为血液中激素测定的首选方法。