Sintzoff S A, Avni E F, Rocmans P, Pardou A, Struyven J
Department of Radiology, Hopital Erasme, Université Libre de Bruxelles, Belgium.
Pediatr Radiol. 1991;21(2):143-4. doi: 10.1007/BF02015633.
A premature baby boy presented at birth with respiratory distress. A right lower lobe opacity was found on chest X-ray. Pulmonary sequestration was the diagnosis suggested by ultrasound. The size of the mass decreased on subsequent examinations. 4 months later X-rays and sonography failed to demonstrate any remaining mass. This case illustrates another example of involutive pathology and suggests that not all pulmonary sequestration-like anomalies should be operated on.