O'Brien K D, Watts D C, Read M J
Orthodontic Unit, University Dental Hospital of Manchester.
Eur J Orthod. 1991 Feb;13(1):22-6. doi: 10.1093/ejo/13.1.22.
A study was undertaken to assess the influence of a low viscosity unfilled 'primer' resin upon the shear bond strength of a bracket adhesive combination to etched enamel and at the separate interfaces of the bonding system, namely the bracket/adhesive and the enamel/adhesive interfaces. No significant differences were detected between the bond strengths when an unfilled resin phase was utilized (P greater than 0.05).