An intra-annular 'hemispherical' annuloplasty frame for aortic valve repair.

作者信息

Rankin J Scott

机构信息

Centennial Medical Center, Vanderbilt University, Nashville, TN, USA.

出版信息

J Heart Valve Dis. 2010 Jan;19(1):97-103.

PMID:20329495
Abstract

BACKGROUND AND AIM OF THE STUDY

A 'Hemispherical' model of aortic valve geometry was developed in which normal human cadaveric aortic valve leaflets could be represented as three hemispheres nested within a cylindrical aorta. By mathematically describing the junction between the leaflets and aorta, the normal three-dimensional annular geometry of the aortic valve could be defined. In this study, a prototype annuloplasty frame based on this model was tested as a repair device in isolated porcine aortic root preparations.

METHODS

Eight isolated porcine aortic roots were perfused with water at a constant pressure of 75 mmHg, and valve leakage was measured before and after the vertical incision of one to three sub-commissural areas to create valve incompetence. Annuloplasty frames then were sutured directly to the valve annuli, and the degree of leakage re-determined. The model predicted that the leaflet free-edge length could be used to define the valve diameter necessary to create competence, and this interaction was tested by varying frame size within the protocol. Post-repair leaflet function also was evaluated using high-speed video. Differences were assessed using a two-tailed paired t-test.

RESULTS

All eight normal porcine aortic valves had negligible baseline leak. With sub-commissural incision, the mean (+/- SD) regurgitant volume was increased to 522 +/- 378 ml/min. After annuloplasty frame insertion, the measured leak decreased to 52 +/- 40 ml/min (p = 0.004). The best results were obtained with a frame diameter 5-6 mm smaller than the leaflet free-edge length. Data recorded using high-speed video suggested a normal dynamic valve function after frame insertion.

CONCLUSION

A three-dimensional 'Hemispherical' intra-annular annuloplasty frame was developed for aortic valve repair. Insertion of the frame into the disrupted porcine valve annuli routinely and effectively restored valve competence. These positive initial results support the continued testing and application of this aortic annuloplasty device.

摘要

相似文献

1
An intra-annular 'hemispherical' annuloplasty frame for aortic valve repair.
J Heart Valve Dis. 2010 Jan;19(1):97-103.
2
Technique for aortic valve annuloplasty using an intra-annular "hemispherical" frame.采用环形“半球形”框架进行主动脉瓣环成形术的技术。
J Thorac Cardiovasc Surg. 2011 Oct;142(4):933-6. doi: 10.1016/j.jtcvs.2011.01.039. Epub 2011 Mar 5.
3
A 'hemispherical' model of aortic valvar geometry.主动脉瓣几何形状的“半球形”模型。
J Heart Valve Dis. 2008 Mar;17(2):179-86.
4
[Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep].[新开发的复合无支架猪主动脉瓣膜的血流动力学性能:体外测试及绵羊体内实验]
Zhonghua Yi Xue Za Zhi. 2008 Jul 29;88(29):2059-63.
5
Frame-mounted porcine valve bioprostheses: preparation during aortic-root dilation. Biomechanics and design considerations.
J Thorac Cardiovasc Surg. 1993 Dec;106(6):1181-8.
6
In vitro investigation of aortic valve annuloplasty using prosthetic ring devices.体外研究使用人工瓣环装置对主动脉瓣环成形术。
Eur J Cardiothorac Surg. 2011 Nov;40(5):1127-30. doi: 10.1016/j.ejcts.2011.02.073. Epub 2011 Apr 29.
7
3-D computational analysis of the stress distribution on the leaflets after edge-to-edge repair of mitral regurgitation.二尖瓣反流缘对缘修复术后瓣叶应力分布的三维计算分析
J Heart Valve Dis. 2002 Nov;11(6):810-22.
8
Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: a finite element model.二尖瓣环扩张的柔性与刚性环成形术:有限元模型
J Heart Valve Dis. 1998 Jan;7(1):108-16.
9
The aortic interleaflet triangles annuloplasty: a multidisciplinary appraisal.主动脉瓣间三角瓣环成形术:多学科评估。
Eur J Cardiothorac Surg. 2011 Oct;40(4):851-7. doi: 10.1016/j.ejcts.2010.12.038. Epub 2011 Feb 11.
10
The pulmonary bioprosthetic heart valve: its unsuitability for use as an aortic valve replacement.肺动脉生物人工心脏瓣膜:其不适用于作为主动脉瓣膜置换物。
J Heart Valve Dis. 2002 Sep;11(5):668-78; discussion 679.