Suppr超能文献

角膜塑形术后近视患者的周边屈光

Peripheral refraction in myopic patients after orthokeratology.

作者信息

Queirós António, González-Méijome José Manuel, Jorge Jorge, Villa-Collar César, Gutiérrez Angel R

机构信息

Clinical and Experimental Optometry Research Laboratory, Department of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal.

出版信息

Optom Vis Sci. 2010 May;87(5):323-9. doi: 10.1097/OPX.0b013e3181d951f7.

Abstract

PURPOSE

The purpose of this study was to characterize the central and peripheral refraction across the horizontal meridian of the visual field before and after myopic corneal refractive therapy (CRT) with contact lenses.

METHODS

Twenty-eight right eyes from 28 subjects (mean age +/- SD = 24.6 +/- 6.3 years) were fitted with Paragon CRT contact lenses to treat myopia between -0.88 and -5.25 D of spherical equivalent. Along with a complete set of examination procedures to assess suitability for treatment, the central and peripheral refractions were measured along the horizontal meridian up to 35 degrees of eccentricity in the nasal and temporal retinal area in 5 degrees steps.

RESULTS

Baseline central average spherical equivalent (M) measured by subjective refraction changed from -1.95 +/- 1.27 D to -0.38 +/- 0.67 D. Changes in M component ranged between 1.42 +/- 0.89 D at center and 0.43 +/- 0.88 D at 20 degrees in the temporal retina (p < 0.002). At 25 degrees to both sides of the central refraction measurement, peripheral refraction after treatment was not statistically different from baseline values (p > 0.351). Beyond the 25 degrees limit, M component changed in the myopic direction up to -1.11 +/- 0.88 D at 35 degrees in temporal retina (p < 0.001). Treatment induced was symmetric between nasal and temporal visual field along the horizontal meridian (p > 0.05 for all eccentricities). Furthermore, the degree of myopic increase in spherical equivalent for 30 degrees (r2 = 0.573, p < 0.001) and 35 degrees (r2 = 0.645, p < 0.001) eccentric refraction was highly correlated with axial spherical equivalent at baseline.

CONCLUSIONS

CRT inverts the pattern of peripheral refraction in spherical equivalent refraction, creating a treatment area of myopic reduction within the central 25 degrees of visual field, and a myopic shift beyond the 25 degrees. In peripheral refraction for 30 degrees and 35 degrees, the amount of myopia induced in terms of spherical equivalent has an almost 1:1 relationship with the amount of baseline spherical equivalent refraction to be corrected.

摘要

目的

本研究旨在描述近视角膜屈光治疗(CRT)隐形眼镜矫正前后,视野水平子午线方向上的中央和周边屈光情况。

方法

对28名受试者的28只右眼(平均年龄±标准差 = 24.6±6.3岁)验配Paragon CRT隐形眼镜,以矫正等效球镜度在-0.88至-5.25 D之间的近视。除了一套完整的评估治疗适用性的检查程序外,还沿水平子午线在鼻侧和颞侧视网膜区域以5度步长测量了高达35度偏心率处的中央和周边屈光。

结果

主观验光测得的基线中央平均等效球镜度(M)从-1.95±1.27 D变为-0.38±0.67 D。M分量的变化在中央为1.42±0.89 D,在颞侧视网膜20度处为0.43±0.88 D(p < 0.002)。在中央屈光测量两侧25度处,治疗后的周边屈光与基线值无统计学差异(p > 0.351)。超过25度界限后,M分量在颞侧视网膜35度处向近视方向变化至-1.11±0.88 D(p < 0.001)。治疗在水平子午线上鼻侧和颞侧视野之间是对称的(所有偏心率下p > 0.05)。此外,30度(r2 = 0.573,p < 0.001)和35度(r2 = 0.645,p < 0.001)偏心屈光的等效球镜度近视增加程度与基线轴向等效球镜度高度相关。

结论

CRT改变了等效球镜屈光中周边屈光的模式,在视野中央25度范围内形成了近视降低的治疗区域,在25度以外则出现近视偏移。在30度和35度的周边屈光中,等效球镜度引起的近视量与需要矫正的基线等效球镜屈光量几乎呈1:1关系。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验