Department of Trauma Surgery, Evangelisches Krankenhaus Luetgendortmund, Volksgartenstrasse 40, Dortmund, Germany.
Knee Surg Sports Traumatol Arthrosc. 2010 Sep;18(9):1252-6. doi: 10.1007/s00167-010-1112-6. Epub 2010 Apr 8.
The objective of this study was to evaluate the position of a K-wire drilled into the lowest and most shallow position possible in the femoral footprint of the anterior cruciate ligament (ACL) with an over-the-top drill guide and to compare this position in relation to the total length of the femoral footprint. In eight specimens, the K-wire was drilled through the guide from the medial side to mimic the anteromedial portal used during arthroscopy. The distances between the K-wire and the farthest points of the anteromedial (AM) and posterolateral (PL) end of the ACL footprint were measured. The median ACL footprint was 15 mm (range 14-18). The median distance from the K-wire was 5 mm (range 3-8) to the AM end of the footprint and 10 mm (range 9-15) to the PL end of the footprint. The K-wire did not reach the middle of the ACL footprint length in any of the specimens. The posterior border of the articular cartilage on the lateral femoral condyle prevented the drill guide from being placed in a lower and more shallow position. The results of this study showed that a tunnel drilled using an over-the-top drill guide and placed in the lowest and most shallow position possible within the ACL footprint is almost exclusively situated in the AM bundle origin.
本研究的目的是评估在 ACL(前交叉韧带)股骨附着点的最下方和最浅位置用过顶钻导针钻入 K 线,并比较其与股骨附着点总长度的关系。在 8 个标本中,导针从内侧穿过导针模拟关节镜检查中使用的前内入路。测量 K 线与 ACL 附着点的最前点(AM)和后外侧(PL)之间的距离。ACL 附着点的中位数为 15mm(范围 14-18)。K 线距 AM 端附着点 5mm(范围 3-8),距 PL 端附着点 10mm(范围 9-15)。在任何标本中,K 线都未到达 ACL 附着点长度的中间位置。外侧股骨髁关节软骨的后缘防止钻导针放置在更低和更浅的位置。本研究结果表明,使用过顶钻导针钻入的隧道,并放置在 ACL 附着点的最下方和最浅位置,几乎完全位于 AM 束起点。