J Dent. 2010 Jul;38(7):553-9. doi: 10.1016/j.jdent.2010.03.015. Epub 2010 Apr 8.
The aim of the present study was to compare the fit of all-ceramic crowns fabricated from intraoral digital impressions with the fit of all-ceramic crowns fabricated from silicone impressions.
Twenty patients agreed to take part in the study to receive two Lava crowns each for the same preparation. One crown was fabricated from intraoral scans using the Lava Chairside Oral Scanner (Lava C.O.S.), and the other crown from a two-step silicone impression. Prior to cementation the fit of both crowns was clinically evaluated by two calibrated and blinded examiners; the marginal fit was also scored from replicas. Data from the replica scores were analysed by Anderson-Darling test, Levene's test and Mann-Whitney test. All tests were performed with alpha-level of 0.05.
Median marginal gap in the conventional impression group was 71microm (Q1:45microm; Q3:98microm), and in the digital impression group 49microm (Q1:32microm; Q3:65microm). Mann-Whitney test revealed a significant difference between the groups (p<0.05). No differences were found regarding the occlusion, and there was a trend for better interproximal fit for the digitally fabricated crowns.
本研究的目的是比较口内数字印模和硅橡胶印模制作的全瓷冠的适合性。
20 名患者同意参与本研究,为同一预备体各接受 2 个 Lava 冠。一个冠由 Lava 椅旁口内扫描仪(Lava C.O.S.)进行口内扫描制作,另一个由两步硅橡胶印模制作。在粘固之前,由两名经过校准和盲法检查的检查者对两个冠的适合性进行临床评估;还从代型上对边缘适合性进行评分。使用 Anderson-Darling 检验、Levene 检验和 Mann-Whitney 检验对代型评分数据进行分析。所有检验的α水平均为 0.05。
传统印模组的中位边缘间隙为 71μm(Q1:45μm;Q3:98μm),数字印模组为 49μm(Q1:32μm;Q3:65μm)。Mann-Whitney 检验显示两组间有显著差异(p<0.05)。在咬合方面无差异,数字化制作的冠在近中邻接方面有更好的趋势。