OBJECTIVE

To perform a systematic review on the reliability of ultrasonographic (US) synovitis detection in rheumatoid arthritis (RA) by B-mode and power Doppler (PD) in image acquisition and still-image interpretation. US is a sensitive method for synovitis detection. However, reliability is still a key concern.

METHODS

Articles reporting any US reliability results for synovitis in RA in PubMed, EMBase, the Cochrane Library, and meeting abstracts were selected. Data were extracted from the collection of data on US synovitis detection (either qualitatively [binary] or semiquantitatively [0-3 scale], for intraobserver and interobserver reliability in B-mode and PD, and for image acquisition and still-image interpretation). The type of joints tested, the experience of the ultrasonographer, and the quality of the studies were assessed. Data analysis involved descriptive and graphic interpretation of reliability and its potential determinants.

RESULTS

Thirty-five studies (12 for B-mode, 11 for PD, or 12 for both) with a total of 1,415 patients were analyzed. Intraobserver and interobserver reliability for still images in B-mode and PD was high (kappa = 0.5-1.0 [14,991 joints] for intraobserver reliability for B-mode, kappa = 0.59-1.0 [14,934 joints] for PD, kappa = 0.49-1.0 [3,138 joints] for interobserver for B-mode, and kappa = 0.66-1.0 [3,325 joints] for PD). Interobserver reliability for image acquisition in both US modes was lower than still-image interpretation (kappa = 0.22-0.95). Few studies reported intraobserver image acquisition reliability.

CONCLUSION

Intraobserver and interobserver reliability of still-image interpretation was high, especially for PD, in published studies involving highly trained observers. However, reliability of acquisition of US should be further assessed.

摘要

目的

对 B 型和能量多普勒(PD)超声在图像采集和静态图像解读中检测类风湿关节炎(RA)滑膜炎症的可靠性进行系统评价。超声是一种检测滑膜炎的敏感方法,但可靠性仍是关键关注点。

方法

检索 PubMed、EMBase、Cochrane 图书馆和会议摘要中有关 RA 超声滑膜炎检测任何可靠性结果的文章。从超声滑膜炎检测数据(定性[二进制]或半定量[0-3 级],用于观察者内和观察者间 B 型和 PD 的可靠性,以及用于图像采集和静态图像解读)中提取数据。评估测试关节的类型、超声医师的经验和研究质量。数据分析包括对可靠性及其潜在决定因素的描述性和图形解释。

结果

分析了 35 项研究(12 项用于 B 型,11 项用于 PD,或 12 项用于两者),共 1415 例患者。B 型和 PD 的静态图像观察者内和观察者间可靠性较高(B 型观察者内可靠性的 Kappa 值为 0.5-1.0[14,991 个关节],PD 的 Kappa 值为 0.59-1.0[14,934 个关节],B 型观察者间可靠性的 Kappa 值为 0.49-1.0[3,138 个关节],PD 的 Kappa 值为 0.66-1.0[3,325 个关节])。两种超声模式的观察者间图像采集可靠性均低于静态图像解读(Kappa 值为 0.22-0.95)。很少有研究报告了观察者内图像采集可靠性。

结论

在发表的研究中,高度训练有素的观察者的静态图像解读的观察者内和观察者间可靠性较高,特别是 PD。然而,应进一步评估超声采集的可靠性。