Department of Radiology/Neuroradiology, University of Bonn Medical Center, Sigmund-Freud-Strasse 25, 53105 Bonn, Germany.
Clin Neuroradiol. 2010 Jun;20(2):99-107. doi: 10.1007/s00062-010-0001-1. Epub 2010 May 21.
Streak artifacts caused by aneurysm clips and coils impede image quality in multidetector computed tomography (MDCT). The authors propose a technique to minimize these artifacts by gated data reconstruction and shifting the reconstruction window.
Intracranial CT angiograms were acquired in the follow-up of six patients with clipped and coiled intracranial aneurysms, respectively. Images were reconstructed from four consecutive 45 degrees rotated segments with an acquisition time of 52.5 ms/segment. Data acquisition was gated via an external pacemaker cable-connected to the scanner.
Artifact orientation could be rotated by shifting the reconstruction window and interesting vessel segments visualized without disturbing streak artifacts. This allowed to assess the posterior communicating artery origin in two cases and a middle cerebral artery aneurysm remnant in another case, respectively. However, due to a higher noise interesting vessel segments were not adjustable in another three patients.
Gated MDCT is a promising technique to reduce the amount and to change the position of artifacts induced by clips or coils.
动脉瘤夹和线圈引起的条纹伪影会影响多排螺旋 CT(MDCT)的图像质量。作者提出了一种通过门控数据重建和调整重建窗来最小化这些伪影的技术。
对分别接受夹闭和线圈栓塞治疗的 6 例颅内动脉瘤患者进行了颅内 CT 血管造影检查。图像是由连续的 4 个 45 度旋转段采集的,每段采集时间为 52.5ms。数据采集通过外部起搏器电缆与扫描仪相连进行门控。
通过调整重建窗,可以旋转伪影的方向,同时可以观察到没有干扰条纹伪影的感兴趣血管段。这分别允许评估两个病例的后交通动脉起源和另一个病例的大脑中动脉动脉瘤残端。然而,由于噪声较高,另外 3 名患者的感兴趣血管段无法调节。
门控 MDCT 是一种有前途的技术,可以减少夹和线圈引起的伪影的数量和改变其位置。