Suppr超能文献

减少CT血管造影上的动脉瘤夹伪影:技术说明

Reduction of aneurysm clip artifacts on CT angiograms: a technical note.

作者信息

Brown J H, Lustrin E S, Lev M H, Ogilvy C S, Taveras J M

机构信息

Department of Radiology, St. Elizabeth Hospital, Elizabeth, NJ, USA.

出版信息

AJNR Am J Neuroradiol. 1999 Apr;20(4):694-6.

Abstract

We describe a head tilt technique for use with CT angiography that reduces beam-hardening artifacts in patients with aneurysm clips. This simple maneuver directs the artifacts away from pertinent anatomy, thus increasing the chances for diagnostic accuracy. No significant changes in the CT angiographic protocol are required, and the maneuver can easily be combined with other artifact-minimizing strategies.

摘要

我们描述了一种用于CT血管造影的头部倾斜技术,该技术可减少患有动脉瘤夹的患者中的束硬化伪影。这种简单的操作可将伪影引导至远离相关解剖结构的位置,从而提高诊断准确性的几率。无需对CT血管造影方案进行重大更改,并且该操作可轻松与其他减少伪影的策略相结合。

相似文献

2
Gated multidetector computed tomography. A technique to reduce intracranial aneurysm clip and coil artifacts.
Clin Neuroradiol. 2010 Jun;20(2):99-107. doi: 10.1007/s00062-010-0001-1. Epub 2010 May 21.
8
Vascular assessment after clipping surgery using four-dimensional CT angiography.
Neurosurg Rev. 2019 Mar;42(1):107-114. doi: 10.1007/s10143-018-0962-0. Epub 2018 Mar 3.
10
The utility of dual-energy CT for metal artifact reduction from intracranial clipping and coiling.
Radiologia (Engl Ed). 2018 Jul-Aug;60(4):312-319. doi: 10.1016/j.rx.2018.02.009. Epub 2018 Apr 23.

引用本文的文献

2
Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study.
Dentomaxillofac Radiol. 2021 Mar 1;50(3):20200365. doi: 10.1259/dmfr.20200365. Epub 2020 Oct 8.
3
Reducing metal artifacts between implants in cone-beam CT by adjusting angular position of the subject.
Oral Radiol. 2021 Jul;37(3):385-394. doi: 10.1007/s11282-020-00458-7. Epub 2020 Jul 7.
4
Iterative Algorithms Applied to Treated Intracranial Aneurysms.
Clin Neuroradiol. 2019 Dec;29(4):741-749. doi: 10.1007/s00062-018-0701-5. Epub 2018 Jun 19.
5
Vascular assessment after clipping surgery using four-dimensional CT angiography.
Neurosurg Rev. 2019 Mar;42(1):107-114. doi: 10.1007/s10143-018-0962-0. Epub 2018 Mar 3.
7
Quantitative analysis of factors affecting cobalt alloy clip artifacts in computed tomography.
J Korean Neurosurg Soc. 2014 Nov;56(5):400-4. doi: 10.3340/jkns.2014.56.5.400. Epub 2014 Nov 30.
8
Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions.
Eur Radiol. 2013 Oct;23(10):2687-94. doi: 10.1007/s00330-013-2885-z. Epub 2013 May 19.
9
Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT.
Dentomaxillofac Radiol. 2013;42(4):20120105. doi: 10.1259/dmfr.20120105. Epub 2013 Feb 18.
10
The value of dual-energy CTA for control of surgically clipped aneurysms.
Eur Radiol. 2011 Oct;21(10):2193-201. doi: 10.1007/s00330-011-2147-x. Epub 2011 May 10.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验