Knisley S B, Maruyama T, Buchanan J W
Division of Cardiology, University of North Carolina, Chapel Hill.
Biophys J. 1991 Mar;59(3):509-15. doi: 10.1016/S0006-3495(91)82267-6.
Theoretical simulations have suggested that interstitial potential (Vis) during action potential propagation affects measurements of the transmembrane action potential in bathed ventricular muscle. To evaluate the Vis experimentally, we obtained Vis and intracellular action potential (Vic) recordings at various depths in paced guinea pig papillary muscles bathed in oxygenated Tyrode's solution. The peak-to-peak amplitude and the maximum dV/dt (dV/dtmax) of the intrinsic downward deflection of the Vis recordings were determined. The transmembrane action potential (TM) was obtained by subtracting each Vis from the corresponding Vic recording, and measurements for the phase zero depolarization and action potential foot of the Vic were compared with the measurements for the TM. At penetration depths of approximately 54 microns, the amplitude and dV/dtmax of the Vis were 13 mV and -38 V/s. When the depth was increased to 200 microns, these parameters increased to 24 mV and -59 V/s (P less than 0.005), and when the depth was further increased to 390 microns, the parameters decreased to 16 mV and -38 V/s. Because of the Vis at the various depths, the Vic underestimated dV/dtmax of phase zero of the TM by 20-31%, which would reduce estimates of Na+ current obtained from dV/dt. Also, the Vic overestimated the time constant of the 2-8 mV foot of the action potential by 48-82%, which would reduce estimates of the "effective" membrane capacitance by 33-45%. These influences of the Vis on measurements may affect results of quantitative studies of the ventricular action potential.
理论模拟表明,动作电位传播期间的细胞间质电位(Vis)会影响浸泡在 Tyrode 溶液中的心室肌跨膜动作电位的测量。为了通过实验评估 Vis,我们在浸泡于含氧 Tyrode 溶液中的豚鼠乳头肌不同深度处获取了 Vis 和细胞内动作电位(Vic)记录。确定了 Vis 记录的峰峰值幅度以及固有向下偏转的最大 dV/dt(dV/dtmax)。通过从相应的 Vic 记录中减去每个 Vis 来获得跨膜动作电位(TM),并将 Vic 的零相去极化和动作电位底部的测量值与 TM 的测量值进行比较。在穿透深度约为 54 微米时,Vis 的幅度和 dV/dtmax 分别为 13 mV 和 -38 V/s。当深度增加到 200 微米时,这些参数增加到 24 mV 和 -59 V/s(P 小于 0.005),当深度进一步增加到 390 微米时,参数降至 16 mV 和 -38 V/s。由于不同深度处的 Vis,Vic 低估了 TM 零相的 dV/dtmax 达 20 - 31%,这会降低从 dV/dt 获得的 Na⁺电流估计值。此外,Vic 高估了动作电位 2 - 8 mV 底部的时间常数达 48 - 82%,这会使“有效”膜电容估计值降低 33 - 45%。Vis 对测量的这些影响可能会影响心室动作电位定量研究的结果。