Andersson M, Eliasson L, Pendrill L R
Appl Opt. 1987 Nov 15;26(22):4835-40. doi: 10.1364/AO.26.004835.
The use of a long, thermally stable Fabry-Perot etalon as a refractometer is considered in detail in this study of the refractive index of air. The etalon consists of two flat plates of fused silica 60 mm in diameter, with a cylindrical spacer made of Zerodur (a polycrystalline glass ceramic of extremely low thermal expansion) 200 mm long. The interferogram of light from a frequency-stabilized He-Ne laser is imaged with large-diameter mirror optics. The principal result is a demonstration of the effects of changes in atmospheric pressure on the etalon. The measured refractive-index values deviate by 2 parts in 10(7) from calculated values. Possible causes of error are considered in detail.
在这项关于空气折射率的研究中,详细探讨了使用长的、热稳定的法布里 - 珀罗标准具作为折射仪的情况。该标准具由两块直径60毫米的熔融石英平板组成,中间有一个由微晶玻璃(一种热膨胀极低的多晶玻璃陶瓷)制成的200毫米长的圆柱形间隔物。来自频率稳定的氦氖激光器的光的干涉图通过大直径镜面光学系统成像。主要结果是展示了大气压力变化对标准具的影响。测量得到的折射率值与计算值相差10的7次方分之二。详细考虑了可能的误差原因。