Suppr超能文献

利用亲水相互作用液相色谱-电喷雾电离串联质谱法直接测定死后尿液标本中的乙基葡萄糖醛酸苷和乙基硫酸盐。

Direct determination of ethyl glucuronide and ethyl sulfate in postmortem urine specimens using hydrophilic interaction liquid chromatography-electrospray ionization-tandem mass spectrometry.

机构信息

University of Glasgow, United Kingdom.

出版信息

J Anal Toxicol. 2010 Jun;34(5):261-72. doi: 10.1093/jat/34.5.261.

Abstract

This work was aimed at developing and validating a hydrophilic interaction chromatography (HILIC)-electrospray ionization (ESI)-ion trap-tandem mass spectrometric method for identification and quantification of ethyl glucuronide (ETG) and ethyl sulfate (ETS) as ethanol biomarkers and at employing this method for analysis of postmortem urine samples. Analytes of interest were separated on a ZIC-HILIC column (150 x 2.1 mm, 3.5 microm) connected to a Thermo Finnigan LCQ Deca Plus liquid chromatographic- tandem mass spectrometric instrument operated in the ESI-selected reaction monitoring mode. Seventy-nine urine case samples were divided into three groups depending on the ethanol concentration found in blood and analyzed by the developed method: group A with postmortem blood ethanol concentrations higher than 200 mg/100 mL; group B with ethanol concentrations in the range 80-200 mg/100 mL; and group C with ethanol concentrations in the range 10-80 mg/100 mL. ETG and ETS had high recoveries of 98-99%, and the HILIC column produced fine, sharp peak shapes and achieved baseline separation in less than 7 min. Both ethanol markers were detected in all groups with overall median concentrations of 100 and 23 mg/L for ETG and ETS, respectively. It can be concluded that the potential for postmortem production of alcohol increased in the low ethanol concentration group as several cases tested negative for both biomarkers in group C. ETG was detected at low concentrations in some cases for which ETS tested negative. Although ETS is stable after being subjected to many stability conditions, the use of ETS as sole evidence of alcohol ingestion may lead to a false-negative result, as we noticed in groups A and C in the present study. The use of ETG is a more reliable ethanol biomarker. Both ethanol biomarkers should be determined in heavily putrefied cases and when the ethanol concentration in postmortem blood is low.

摘要

本研究旨在开发并验证一种亲水作用色谱(HILIC)-电喷雾电离(ESI)-离子阱串联质谱法,用于鉴定和定量乙醇生物标志物乙基葡萄糖醛酸苷(ETG)和乙基硫酸盐(ETS),并将该方法应用于分析死后尿液样本。采用 Thermo Finnigan LCQ Deca Plus 液相色谱-串联质谱仪,在 ESI 选择反应监测模式下运行,在 ZIC-HILIC 柱(150×2.1mm,3.5μm)上对目标分析物进行分离。根据血液中乙醇浓度的不同,将 79 例尿液案例样本分为三组,并采用所建立的方法进行分析:组 A 为死后血液乙醇浓度高于 200mg/100mL;组 B 为乙醇浓度在 80-200mg/100mL 范围内;组 C 为乙醇浓度在 10-80mg/100mL 范围内。ETG 和 ETS 的回收率均在 98%-99%之间,且 HILIC 柱产生的峰形尖锐、精细,不到 7 分钟即可实现基线分离。所有组均检测到 ETG 和 ETS 这两种乙醇标志物,ETG 和 ETS 的总中位数浓度分别为 100mg/L 和 23mg/L。由此可以得出结论,低乙醇浓度组死后产生酒精的可能性增加,因为在组 C 中,有几个案例这两种生物标志物均检测为阴性。在一些 ETS 检测结果为阴性的案例中,检测到 ETG 浓度较低。尽管 ETS 在经受多种稳定性条件后仍然稳定,但单独使用 ETS 作为摄入酒精的唯一证据可能会导致假阴性结果,正如本研究中在组 A 和组 C 中所注意到的那样。使用 ETG 是一种更可靠的乙醇生物标志物。在严重腐败的案例和死后血液中乙醇浓度较低的情况下,都应同时测定 ETG 和 ETS。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验