Suppr超能文献

双源 CT 双能量 CT 血管造影评估脑动脉。

Cerebral artery evaluation of dual energy CT angiography with dual source CT.

机构信息

Shandong Medical Imaging Research Institute, Shandong University, Jinan, Shandong 250021, China.

出版信息

Chin Med J (Engl). 2010 May 5;123(9):1139-44.

Abstract

BACKGROUND

Conventional computed tomography angiography (CTA) is time consuming, user-dependent and has poor image quality in skull base region. This study assessed the feasibility of a new method, dual energy CTA for depicting the cerebral artery.

METHODS

Phantom scan was done with head CTA sequences on dual source CT and 64 spiral CT for radiation dose calculation. Dual energy CTA was done with dual source CT on 36 patients who were suspected of having cerebral vascular disease. Three series axial images in 0.75 mm thick, 0.4 mm increment were acquired, which were named with 80 kV, 140 kV and merged images; 80 kV and 140 kV images were transferred into dual energy software, and maximum intensity projection (MIP) image was generated quickly by dual energy bone remove (DEBR group); merged images were transferred into In Space software to acquire MIP image through manual conventional bone remove (CoBR group). Post processing time and reading time were compared. Image qualities of the two groups were compared, mainly focusing on skull base segments of internal carotid artery and bone subtraction. ANOVA and SNK tests were applied for radiation dose comparison. Student's t test and Wilcoxon rank sum test were applied for assessing differences between data for significance. Cohen's kappa was used for interobserver agreement.

RESULTS

Radiation dose of phantom scan showed dual energy CTA was between digital bone subtraction and conventional CTA. The post processing time and reading time were much shorter in DEBR than CoBR, and image quality in skull base was much higher in DEBR than CoBR (P < 0.01). There was no significant difference for suprasellar vessels between two groups (P > 0.5). Interobserver agreement for all vessel segments was excellent (kappa = 0.97).

CONCLUSIONS

Dual energy CTA is a reliable, new modality for depicting cerebral artery, overcoming the limitation of conventional CTA in the skull base region. It can save much time in post processing and reading than conventional CTA.

摘要

背景

传统的计算机断层血管造影(CTA)在颅底区域耗时、依赖用户且图像质量差。本研究评估了一种新方法,即双能 CTA 显示脑动脉的可行性。

方法

使用头部 CTA 序列在双源 CT 和 64 螺旋 CT 上进行体模扫描,以计算辐射剂量。对 36 例疑似脑血管疾病的患者进行双能 CTA 检查。采集 0.75mm 厚、0.4mm 层厚的 3 个系列轴位图像,分别命名为 80kV、140kV 及融合图像;将 80kV 和 140kV 图像传输至双能软件,通过双能骨去除(DEBR 组)快速生成最大密度投影(MIP)图像;将融合图像传输至 In Space 软件,通过手动常规骨去除(CoBR 组)获取 MIP 图像。比较两组的后处理时间和阅读时间。比较两组图像质量,主要观察内颈动脉颅底段和骨去除情况。采用方差分析和 SNK 检验比较辐射剂量,采用 Student's t 检验和 Wilcoxon 秩和检验比较数据差异的显著性,采用 Cohen's kappa 检验观察者间一致性。

结果

体模扫描的辐射剂量显示,双能 CTA 介于数字骨去除和传统 CTA 之间。DEBR 的后处理时间和阅读时间明显短于 CoBR,DEBR 的颅底图像质量明显高于 CoBR(P<0.01)。两组间鞍上血管无显著差异(P>0.5)。所有血管节段的观察者间一致性均极好(kappa=0.97)。

结论

双能 CTA 是一种可靠的、显示脑动脉的新方法,克服了传统 CTA 在颅底区域的局限性。与传统 CTA 相比,它在图像后处理和阅读方面节省了大量时间。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验