Walters M A, Blumenthal N C, Leung Y, Wang Y, Ricci J L, Spivak J M
Department of Chemistry, New York University, NY 10003.
Calcif Tissue Int. 1991 May;48(5):368-9. doi: 10.1007/BF02556157.
Test implant plates surgically retrieved from distal femurs of dogs were studied by Raman spectroscopy in order to characterize the bone-implant interface. The implant surface consisted of phosphate mineral, plasma sprayed on a titanium substrate. On the basis of its spectroscopic signature, the phosphate mineral of bone and the implant surface formed a mixed phase in the interface.
对通过手术从狗的股骨远端取出的测试植入板进行了拉曼光谱研究,以表征骨 - 植入物界面。植入物表面由喷涂在钛基底上的磷酸盐矿物质组成。根据其光谱特征,骨中的磷酸盐矿物质与植入物表面在界面处形成了混合相。