Suppr超能文献

一项评估预防性氟化物制剂对镍钛丝超弹性性能影响的临床试验。

A clinical trial to evaluate the effects of prophylactic fluoride agents on the superelastic properties of nickel-titanium wires.

作者信息

Vo Jossette, Chudasama Dipak N, Rinchuse Donald J, Day Richard

机构信息

School of Orthodontics, Jacksonville University, Jacksonville, Florida, USA.

出版信息

World J Orthod. 2010 Summer;11(2):135-41.

Abstract

AIM

To study the effects of a prophylactic fluoride regimen on the mechanical properties of nickel-titanium (Ni-Ti) archwires under clinical conditions.

METHOD

The unloading properties of 100 Ni-Ti wires were tested using a three-point bending test at five deflections (0.5 mm, 1.0 mm, 2.0 mm. 3.0 mm, and 3.1 mm). Sixty-six 0.016 3 0.022-inch Ni-Ti wires were tested after being used intraorally for 6 weeks using two protocols. Thirty-three wires were evaluated after the use of fluoride-containing Crest toothpaste (sodium fluoride 0.243%, 0.15% w/v fluoride ion) and Equate fluoride rinse (sodium fluoride 0.05%, fluoride ion 0.0226%). Another 33 wires were examined after a nonfluoridated natural toothpaste (Tom's of Maine; calcium carbonate, xylitol, myrrh, propolis, sodium lauryl sulfate, carrageenan, spearmint and peppermint oils, glycerin, and water) was used. Another 34 Ni-Ti wires served as a control; they were tested as received. Statistical analyses were carried out with a linear-mixed model (analysis of variance [ANOVA]).

RESULTS

Force degradation occurred within both groups of intraorally used wires but not in the unused archwires. When compared to unexposed wires, those with fluoride exposure exhibited slightly higher force degradation at 3.1 and 3.0 mm deflection, but they displayed less force degradation at 0.5 and 1.0 mm deflection.

CONCLUSIONS

Topical fluoride regimens decreased the unloading property of Ni-Ti wires at higher deflections but increased it at lower deflections.

摘要

目的

研究预防性氟化物治疗方案在临床条件下对镍钛(Ni-Ti)弓丝力学性能的影响。

方法

使用三点弯曲试验在五个挠度(0.5毫米、1.0毫米、2.0毫米、3.0毫米和3.1毫米)下测试100根Ni-Ti丝的卸载性能。66根0.016×0.022英寸的Ni-Ti丝在口腔内使用6周后,按照两种方案进行测试。33根丝在使用含氟的佳洁士牙膏(氟化钠0.243%,氟离子0.15% w/v)和Equate含氟漱口水(氟化钠0.05%,氟离子0.0226%)后进行评估。另外33根丝在使用不含氟的天然牙膏(缅因汤姆;碳酸钙、木糖醇、没药、蜂胶、月桂醇硫酸酯钠、卡拉胶、留兰香和薄荷油、甘油和水)后进行检查。另外34根Ni-Ti丝作为对照;按收到时的状态进行测试。采用线性混合模型(方差分析[ANOVA])进行统计分析。

结果

两组口腔内使用的丝均出现力值下降,但未使用的弓丝未出现。与未暴露的丝相比,暴露于氟化物的丝在挠度为3.1和3.0毫米时力值下降略高,但在挠度为0.5和1.0毫米时力值下降较小。

结论

局部氟化物治疗方案在较高挠度下降低了Ni-Ti丝的卸载性能,但在较低挠度下提高了卸载性能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验