Suppr超能文献

手绘图与头影测量分析计算机程序的比较——有无高级功能的准确性和时间需求。

A comparison of hand-tracing and cephalometric analysis computer programs with and without advanced features--accuracy and time demands.

机构信息

Department of Orthodontics, Institute of Odontology, Karolinska Institutet, Huddinge, Sweden.

出版信息

Eur J Orthod. 2010 Dec;32(6):721-8. doi: 10.1093/ejo/cjq009. Epub 2010 Jun 16.

Abstract

The aim of this study was to evaluate the basic and advanced features of five different cephalometric analysis computer programs. The level of measurement agreement with hand-tracing and time demands was examined. The material consisted of 30 digital lateral radiographic images. Twenty-three measurements were calculated by one operator both manually and using five different cephalometric analysis software programs. Intraclass correlation coefficient (ICC) was used to detect differences in measurement agreement between hand-tracing and basic features as well as between hand-tracing and advanced features. Coefficient of variation (CV) was used to assess intra-user error and a Student's t-test to determine time differences. Of the 23 measurements tested for each procedure, one [(Ii to NB (mm)] showed better agreement with hand-tracing when the advanced features were used, 20 showed good agreement with hand-tracing for both basic and advanced features, while two (AB on FOP and Ii to A/Pog) showed poor intra-user reproducibility. Hand-tracing took a significantly longer time (P < 0.001) than both the basic and advanced features. The advanced features took a significantly longer time (P < 0.001) than the basic features. Both basic and advanced features showed good measurement agreement with the hand-tracing technique. The use of the basic features minimizes the time requirements for analysis. A computerized tracing technique, which consists of either basic or advanced feature, can be regarded as less time consuming and equally reliable to hand-tracing as far as cephalometric measurements are concerned.

摘要

本研究旨在评估五种不同头影测量分析计算机程序的基本和高级功能。检验了与手工描记的测量一致性和时间需求。材料由 30 个数字化侧位射线影像组成。由一名操作者手动和使用五种不同头影测量分析软件程序分别计算了 23 个测量值。采用组内相关系数(ICC)来检测手工描记与基本特征以及手工描记与高级特征之间测量一致性的差异。变异系数(CV)用于评估用户内误差,学生 t 检验用于确定时间差异。对于每种程序测试的 23 个测量值中的一个[(Ii 至 NB(mm)],当使用高级特征时,与手工描记的一致性更好,20 个测量值在基本和高级特征上均与手工描记具有良好的一致性,而另外两个测量值(AB 至 FOP 和 Ii 至 A/Pog)显示出较差的用户内可重复性。手工描记所需的时间明显长于基本特征和高级特征(P < 0.001)。高级特征所需的时间明显长于基本特征(P < 0.001)。基本特征和高级特征均与手工描记技术具有良好的测量一致性。使用基本特征可将分析的时间要求最小化。无论使用基本特征还是高级特征,计算机描记技术都可以被视为与手工描记一样耗时,并且在头影测量方面同样可靠。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验