Suppr超能文献

数字放射成像在手动与计算机辅助头影测量分析中的速度、重复性和再现性评估。

Evaluation of speed, repeatability, and reproducibility of digital radiography with manual versus computer-assisted cephalometric analyses.

作者信息

Uysal Tancan, Baysal Asli, Yagci Ahmet

机构信息

Department of Orthodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.

出版信息

Eur J Orthod. 2009 Oct;31(5):523-8. doi: 10.1093/ejo/cjp022. Epub 2009 May 14.

Abstract

The aims of this study were to evaluate intra-examiner repeatability and inter-examiner reproducibility of landmarks using two cephalometric analysing techniques, manual and computerized, and to compare these for speed. One hundred lateral cephalometric radiographs were randomly selected and 11 angular and six linear parameters were traced and measured by two examiners using the manual method and Dolphin Image Software 9.0 on each radiograph. A Student's t-test for paired and independent samples was used to compare the mean values of intra- and inter-examiner differences. Intraclass correlation coefficients (ICC) were calculated to determine intra- and inter-examiner correlation (r value). Both operators were generally consistent in the repeated measurements; however, for one examiner, the differences for Na is perpendicular to A (P < 0.001), Na is perpendicular Pog, and U1-NA (P < 0.01) distance measurements were found to be statistically significant. Intra-examiner repeatability of landmarks both with the manual and Dolphin techniques showed high correlation coefficients. While inter-examiner reproducibility of landmarks was unacceptable, measurement errors with the manual technique were generally comparable with the Dolphin technique. The mean tracing times of the two operators for a single tracing was 2 minutes 41 seconds for Dolphin and 6 minutes 51 seconds for manual tracings. Computer-assisted cephalometric analysis does not increase intra- and inter-examiner reliability but can result in time saving.

摘要

本研究的目的是使用两种头影测量分析技术(手动和计算机化)评估检查者内的重复性和检查者间的可重复性,并比较它们的速度。随机选择100张头颅侧位X线片,两名检查者分别使用手动方法和Dolphin Image Software 9.0在每张X线片上描绘并测量11个角度参数和6个线性参数。采用配对样本和独立样本的t检验比较检查者内和检查者间差异的平均值。计算组内相关系数(ICC)以确定检查者内和检查者间的相关性(r值)。两位操作者在重复测量中总体上是一致的;然而,对于一名检查者,发现Na垂直于A(P<0.001)、Na垂直于Pog以及U1-NA(P<0.01)距离测量的差异具有统计学意义。手动和Dolphin技术下头影标志点的检查者内重复性均显示出高相关系数。虽然头影标志点的检查者间可重复性不可接受,但手动技术的测量误差通常与Dolphin技术相当。两名操作者单次描绘的平均追踪时间,使用Dolphin技术为2分41秒,手动描绘为6分51秒。计算机辅助头影测量分析不会提高检查者内和检查者间的可靠性,但可以节省时间。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验