Novel use of the "buddy"wire.

作者信息

O'Hare A, Brennan P, Thornton J

机构信息

Department of Neuroradiology, Beaumont Hospital, Dublin; Ireland -

出版信息

Interv Neuroradiol. 2008 Dec 29;14(4):453-6. doi: 10.1177/159101990801400412. Epub 2009 Jan 5.

Abstract

During interventional procedures the tortuosity of the vasculature hampers catheter stability. The buddy wire may be used to aid and maintain vascular access.We describe a case of acute subarachnoid haemorrhage secondary to dissecting aneurysm of the vertebral artery.We discuss the value of the buddy wire during balloon occlusion of the vertebral artery not as it is typically used, but to actually prevent the balloon repeatedly entering the posterior inferior cerebellar artery during the procedure.