This study analyses 126 cases of dental injuries occurring during endotracheal intubation, reported to the service of litigations of the hospitals in Lyon over a ten-year period, and giving rise to a complaint. The overall rate was 1 out of 4,000 cases of intubation. The true incidence may be greater. As expected, the upper jaw teeth are most often involved, especially the left incisors. Among them 24.3% of the involved teeth were normal. Dental fractures were the most common lesion, together with total or partial dislocations. A questionnaire was sent to 534 anaesthetists to assess the main difficulties which they encounter when carrying out endotracheal intubation. The results of this enquiry demonstrated that anaesthetists were very aware of dental risks when carrying out intubation, and that there was a lack of efficient protective measures. Among them 81.2% claimed they would use a protective device from time to time, and 17.4% routinely, if one were available. Therefore we designed such a device. It is gutter-shaped, made with two different plastics, the more rigid one being on the outside. It fits over the upper jaw teeth. There is an indentation in the front, to check whether the device is placed correctly. The inner surface is made of foam which dulls the pressure which may be exerted on the device during intubation. This device was tested in 108 patients. Intubation was easy with the device in place in 73.2% of patients; mouth opening was reduced by a mean of 4.2 +/- 0.5 mm. The device made intubation more difficult, and even impossible, in patients whose mouth opened no more than 3.5 cm.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究分析了126例在气管插管过程中发生的牙损伤病例,这些病例是里昂各医院诉讼服务部门在十年期间报告的,并引发了投诉。总体发生率为每4000例插管中有1例。实际发生率可能更高。正如预期的那样,上颌牙齿最常受累,尤其是左前牙。其中24.3%的受累牙齿原本正常。牙骨折是最常见的损伤,还有完全或部分脱位。我们向534名麻醉师发放了问卷,以评估他们在进行气管插管时遇到的主要困难。调查结果表明,麻醉师在插管时非常清楚牙齿风险,且缺乏有效的保护措施。其中81.2%的人表示如果有保护装置,他们会偶尔使用,17.4%的人表示会经常使用。因此我们设计了这样一种装置。它呈槽形,由两种不同的塑料制成,较硬的一种在外部。它套在上颌牙齿上。前面有一个凹口,用于检查装置是否放置正确。内表面由泡沫制成,可减轻插管过程中可能施加在装置上的压力。该装置在108名患者身上进行了测试。在73.2%的患者中,使用该装置时插管很容易;平均开口度减小了4.2 +/- 0.5毫米。对于开口度不超过3.5厘米的患者,该装置使插管更加困难,甚至无法进行。(摘要截取自250词)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验