INRA, UMR 1198 Developmental Biology and Reproduction, Jouy-en-Josas, France.
Ultrasound Obstet Gynecol. 2010 Nov;36(5):635-40. doi: 10.1002/uog.7741.
Three-dimensional (3D) Doppler quantification within the uteroplacental unit could be of great help in understanding and screening for pre-eclampsia and intrauterine growth restriction. Yet the correlation between 3D Doppler indices and true blood flow has not been confirmed in vivo. The aim of this study was to evaluate this correlation in a pregnant sheep model.
A blood flow quantitative sensor and a controllable vascular occlusion system were placed around the common uterine artery in seven sheep in late pregnancy, while all the other arterial supplies were ligated. Several occlusion levels were applied, from 0 to 100%, simultaneously with 3D Doppler acquisitions of several placentomes, using standardized settings. Each placentome was analyzed using VOCAL™ (Virtual Organ Computer-aided AnaLysis) software. The correlation between true blood flow and Doppler indices (vascularization index (VI), flow index (FI) and vascularization flow index (VFI)) was evaluated, together with measurement reproducibility.
Forty-eight acquisitions were analyzed. All 3D Doppler indices were significantly correlated with true blood flow. Higher correlations were observed for VI and VFI (r = 0.81 (0.74-0.87), P < 0.0001 and r = 0.75 (0.67-0.82), P < 0.0001) compared with FI (r = 0.53 (0.38-0.64) P < 0.0001). Both intra- and interobserver reproducibility were high, with intraclass correlation coefficients of at least 0.799.
This is the first in-vivo experimental study confirming a significant correlation between true blood perfusion and quantitative 3D Doppler indices measured within the uteroplacental unit. These results confirm the potential usefulness of 3D Doppler ultrasound for the assessment of placental vascular insufficiency both in clinical cases and in a research setting.
在子宫胎盘单位内进行三维(3D)多普勒定量分析可能有助于理解和筛查子痫前期和宫内生长受限。然而,3D 多普勒指数与真实血流之间的相关性尚未在体内得到证实。本研究旨在评估妊娠绵羊模型中的这种相关性。
在妊娠晚期的 7 只绵羊的共用子宫动脉周围放置血流定量传感器和可控血管闭塞系统,同时结扎所有其他动脉供应。应用几个闭塞水平,从 0%到 100%,同时使用标准化设置对几个胎盘进行 3D 多普勒采集。使用 VOCAL™(虚拟器官计算机辅助分析)软件分析每个胎盘。评估真实血流与多普勒指数(血管化指数(VI)、血流指数(FI)和血管化血流指数(VFI))之间的相关性,以及测量的可重复性。
分析了 48 次采集。所有 3D 多普勒指数均与真实血流显著相关。VI 和 VFI 的相关性更高(r = 0.81(0.74-0.87),P < 0.0001 和 r = 0.75(0.67-0.82),P < 0.0001),而 FI 的相关性较低(r = 0.53(0.38-0.64),P < 0.0001)。观察者内和观察者间的可重复性均较高,组内相关系数至少为 0.799。
这是首次在体内实验研究中证实,在子宫胎盘单位内测量的真实血流灌注与定量 3D 多普勒指数之间存在显著相关性。这些结果证实了 3D 多普勒超声在评估胎盘血管功能不全方面的潜在用途,无论是在临床病例中还是在研究环境中。